2HP Commercial Wood Dust Collector Owners Manual
O.A.S. 2002
c
16.1875
VII. Bracket Assembly
1. You must determine the direction the fan outlet will point to
proceed with this mounting assembly. The collector will seem
quieter if the outlet is aimed away from the area people tend to
work. Slots in the brackets are .406 x 1.00
Note: Bolts included to mount bracket to collector. Hardware NOT
included to mount to wall.
2. Mount wall bracket. For wall mounting, the bolt center on the
left bracket will be 21.75 from the bolt center on the right bracket
for the 2hp unit. See Fig. 1.
3. Attach vertical arm of each bracket to wall with lag screws,
concrete anchors, or other suitable hardware. See Fig. 2 & 3.
Note: When installing the brackets on a concrete wall, mount 2
x 4s between wall and brackets to stabilize and dampen vibration.
4. Position Angle Ring holding the fan housing over bracket.
Line up one hole in Ring with hole in each bracket at desired
rotation of outlet (two holes on each side will not line up). If
rotation you desire does not correspond to an existing hole in
Angle Ring, drill new ones. Use two 3/8 bolts (included) with
washers & lock washers to secure the fan. See Fig. 4.
6. Attach tightly with bolts. See Fig. 4.
21.75 2hp
11.25 - 2hp
1
.406 x 1.00
2
3
Note: Please do not install an Oneida Dust Collection System alone. Competent
assistence is advisable. Units are heavy!
4
* Optional Mounting Direction
8