VIII. General Assembly Instructions -
All Models
1. Wire motor according to wiring diagram on page 7. Use a
cord rated for a minimum of 20 Amps. Make sure the cord
you use is rated for the same power as the motor. Always
follow motor plate diagram and wire for correct rotation.
(See
Wiring diagram section)
2. Secure fan assembly to cyclone barrel with ductwork clamp
ring. For final installation, use a small bead of silicone sealant
after positioning outlet and inlet between the two mating halves.
Align the inlet of the cyclone in the proper direction for the
system.
See Fig. 1
.
3. Hang unit from brackets. See Bracket assembly.
4. Attach the cone to the barrel with the metal clamping ring.
Lightly tighten the ring bolt. It is important that there is no air
leakage between the cone and barrel of the collector. There
should be a black rubber seal between the cone and barrel.
See Fig. 2
5. Attach flex hose to bottom of collector and to lid of dust bin.
Securely fasten hose clamps. Cut excess length of flex hose
if needed. Longer flex hoses are available for installations
requiring more height. There must be an air tight seal between
the collector and dust bin.
See Fig. 3
6. Make sure the dust bin lid sits securely and the rubber
gasket on the bin lid is in place on the barrel. Maintain an air
tight seal between cyclone and dust bin to prevent motor from
overheating
due to over amperage draw.
7. Attach the ductwork from the woodworking machines to the
inlet of the collector.
8.
For External Cartridge, Tube Filter or No Filter models
see
following pages 10 and 11.
9. On external filter models, attach Filter Plenum Assembly or
External Cartridge Assembly with 4 bolts.
See Filter Assembly
Section, pages 10 & 11 for details.
O.A.S. 2002
c
Fan
Assembly
Cyclone
Barrel
Clamp
Ring
1
3
Collector
Hose Clamp
Hose Clamp
Flex Hose
Dust Bin
2
Barrel
Cone
Clamp
Ring
Wiring should be done by a licensed electrician!
Rubber
Seal
Outlet
Inlet
2HP Commercial Wood Dust Collector Owners Manual
IMPORTANT:
Do not operate the collector until the dust bin is in place
and the connector is air tight or motor damage could result!
Stay clear of fan exhaust while collector is operating.