NCN49597
http://onsemi.com
12
Power
−
on
−
Reset (POR)
Table 11. POWER
−
ON
−
RESET
Parameter
Test Conditions
Symbol
Min
Typ
Max
Unit
POR threshold
V
POR
1.7
2.7
V
Power supply rise time
0 to 3V
T
RPOR
1
ms
Digital Outputs: TDO, CLK_OUT
Table 12. DIGITAL OUTPUTS: TDO, CLK_OUT
Parameter
Test Conditions
Symbol
Min
Typ
Max
Unit
Low output voltage
I
XOUT
= 4 mA
V
OL
0.4
V
High output voltage
I
XOUT
=
−
4 mA
V
OH
0.85 V
DD
V
Digital Outputs with Open Drain: TX_ENB, TXD
Table 13. DIGITAL OUTPUTS WITH OPEN DRAIN: TX_ENB, TXD, RX_DATA, CRC, T_REQ
Parameter
Test Conditions
Symbol
Min
Typ
Max
Unit
Low output voltage
I
XOUT
= 4 mA
V
OL
0.4
V
Digital Inputs: BR0, BR1
Table 14. DIGITAL INPUTS: BR0, BR1
Parameter
Test Conditions
Symbol
Min
Typ
Max
Unit
Low input level
V
IL
0.2 V
DD
V
High input level
0 to 3 V
V
IH
0.8 V
DD
V
Input leakage current
I
LEAK
−
10
10
m
A
Digital Inputs with Pull Down: TDI, TMS, TCK, TRSTB, TEST
Table 15. DIGITAL INPUTS WITH PULL DOWN: TDI, TMS, TCK, TRSTB, TEST
Parameter
Test Conditions
Symbol
Min
Typ
Max
Unit
Low input level
V
IL
0.2 V
DD
V
High input level
V
IH
0.8 V
DD
V
Pull down resistor
(Note 14)
R
PU
7
50
k
W
14.Measured around a bias point of V
DD
/2.
Digital Schmitt Trigger Inputs: RXD, RESB
Table 16. DIGITAL SCHMITT TRIGGER INPUTS: RXD, RESB
Parameter
Test Conditions
Symbol
Min
Typ
Max
Unit
Rising threshold level
V
T+
0.80 V
DD
V
Falling threshold level
V
T
−
0.2 V
DD
V
Input leakage current
I
LEAK
−
10
10
m
A