Reflective Sensor Heads: FUN Mode Functions
Section 3-5
69
3-5-11 Display Reverse Function
The display direction of the digital displays can be selected. Select either
forward or backward according to the mounting direction of the Amplifier
Unit.
Refer
to
4-5-11 Special FUN Mode Settings Related to Dis-
plays.
3-5-12 ECO Display Function
The ECO display function can be enabled or disabled. When the ECO dis-
play function is enabled, the digital display will not light.
3-5-13 Limiting the Number of Display Digits
The number of display digits of the main display and sub-display can be
set. When the number of digits is reduced, the rightmost digit is disabled
first. In addition, if 0 digits are specified, the entire digital display will be dis-
abled. This applies, however, only in RUN Mode.
3-5-14 Setting for Non-measurement
The output method used during non-measurement can be set. This setting
applies when a reset is input or a reception error occurs.
Maximum output voltage: Approximately 5.5 V
Maximum output current: Approximately 23 mA
Refer
to
4-5-12 Other Special FUN Mode Settings
.
Outputs
Setting for non-measurement
CLAMP
KEEP
Judgement outputs
All OFF.
The status immediately
before measurement
stopped is held.
Linear output
Held at the maximum
output value.
Содержание ZX Series
Страница 1: ...Cat No Z157 E1 01B OPERATION MANUAL ZX Series Smart Sensors ...
Страница 2: ......
Страница 3: ...Smart Sensors ZX Series Operation Manual Cat No Z157 E1 01B OMRON Corporation ...
Страница 48: ...OutlineofFunctions Section 2 5 28 Memo ...
Страница 160: ...FUN Function Mode Section 4 5 140 Memo ...
Страница 166: ...Setting Problems Section 5 2 146 Memo ...
Страница 185: ...Dimensions Section 6 2 165 6 2 4 Calculating Unit n ZX CAL Connectors Connection indicators Unit mm ...
Страница 186: ...Dimensions Section 6 2 166 Memo ...
Страница 187: ......
Страница 188: ...Z157 E1 01B ...