T (Threshold) Mode
Section 4-4
120
n
Automatic Teaching
Automatic teaching is used to automatically set the threshold values at
optimum positions. The threshold values are automatically set in the mid-
dle between the maximum and minimum distance values while the keys
are held down.
Select the threshold value that is to be
taught using the threshold switch.
Press the ENT and RIGHT Keys at the
same time as the workpieces flow.
H L
“AUtot” will flash on the sub-display
after the keys have been pressed for 1
second (sampling, however, will start
immediately after the keys are
pressed).
Sampling will continue while the keys
are pressed.
Release the keys.
Press the ENT and RIGHT
Keys at the same time.
Release the keys.
The threshold value will be automati-
cally set when you release the keys. It
will be set to the middle position
between the maximum and minimum
measured for the sample values.
The automatically set threshold value
will flash on the sub-display twice.
+
The sub-display will light con-
tinuously after flashing twice.
Содержание ZX Series
Страница 1: ...Cat No Z157 E1 01B OPERATION MANUAL ZX Series Smart Sensors ...
Страница 2: ......
Страница 3: ...Smart Sensors ZX Series Operation Manual Cat No Z157 E1 01B OMRON Corporation ...
Страница 48: ...OutlineofFunctions Section 2 5 28 Memo ...
Страница 160: ...FUN Function Mode Section 4 5 140 Memo ...
Страница 166: ...Setting Problems Section 5 2 146 Memo ...
Страница 185: ...Dimensions Section 6 2 165 6 2 4 Calculating Unit n ZX CAL Connectors Connection indicators Unit mm ...
Страница 186: ...Dimensions Section 6 2 166 Memo ...
Страница 187: ......
Страница 188: ...Z157 E1 01B ...