Reflective Sensor Heads: FUN Mode Functions
Section 3-5
45
l
Inverting Display Values
When inverting the display values is set, the display values will be in an
inverse relationship to the reference values.
Normally, the more the distance between Sensor and sensing object
increases, the larger the display value becomes. However, if the display
values are inverted, the more the distance increases, the smaller the dis-
play value will become.
Inverting display values is not possible when two-point scaling is used.
When scaling cannot be set correctly, refer to
5-2-1
Unable to Set Scaling
.
When any of the following changes is performed, the scaling func-
tion is automatically cleared and must be performed again.
• Turning ON or OFF Intensity Mode.
• Enabling or disabling two-sensor operation A + B.
• Enabling or disabling two-sensor operation A
−
B.