Reflective Sensor Heads: FUN Mode Functions
Section 3-5
46
n
Offsetting Display Values: One-point Scaling A
Use one-point scaling to offset the display values. Input the distance to be
displayed for the current measurement point. When you input only one
point for scaling, only the offset is changed without changing the range of
display values. In this example, the display values are not inverted.
Example:
Example: One-point Scaling A
80.0
140.0
80.0
90.0
150.0
90.0
100.0
160.0
100.0
110.0
170.0
110.0
Sensor Head
Although the Y value
must be displayed,
the X value is displayed.
Y
X
If X = 90 mm
and Y = 150 mm,
Sensing object
Measured value = Display value
Measured value
Display value
: Scaling value input
90 mm is displayed as 150 mm.
Display value
(mm)
150.0
90.0
90.0
Actual distance (mm)
Despite the offset, the range
remains unchanged.