F-94
Two-circuit Limit Switch
WL
Installation
Item
Appropriate model/actuator
Details
Changing the installation position of
the actuator
By loosening the Allen-head bolt on the
actuator lever, the position of the actua-
tor can be set anywhere within the 360
°
.
With Lamp-equipped Switches, the actu-
ator lever comes in contact with the top
of the lamp cover, so use caution when
rotating and setting the lever. When the
lever only moves forwards and back-
wards, it will not contact the lamp cover.
Roller Levers: WLCA2, WL01CA2,
WLH2, WL01H2, WLG2, WL01G2
Adjustable Roller Levers: WLCA12,
WL01CA12, WLH12, WL01H12,
WLG12, WL01G12
Adjustable Rod Levers: WLCL,
WL01CL, WLHL, WL01HL, WLGL,
WL01GL
Changing the orientation of the Head
By removing the screws in the four cor-
ners of the Head, the Head can be set in
any of the four directions. Be sure to
change the plunger for internal opera-
tions at the same time. (The operational
plunger does not need to be changed on
overtravel general-purpose and high-
sensitivity models.) The roller plunger
can be set in either two positions at 90
°
.
WLCA2-2N and WL01CA2-2N can only
be set in either the forward or backward
direction.
Roller Levers: WLCA
@
, WL01CA
@
,
WLGCA
@
Adjustable Rod Levers: WLCL,
WL01CL
Horizontal Plungers: WLSD
@
,
WL01SD
@
Roller Plungers: WLD2, WL01D2
Sealed Roller Plungers: WLD28,
WL01D28.
Note:
Does not include -RP60
Series or -141 Series.
WL-5A101
WL-5A103
WL-5A105
WL-5A100 has a resin roller
WL-5A102 has a resin roller
WL-5A104 has a resin roller
7.3
+0.1
dia.
0
7.3
+0.1
dia.
0
7.3
+0.1
dia.
0
Two, 17.5 dia. (length: 7)
stainless sintered alloy
rollers
Two, 17.5 dia. (length: 7)
stainless sintered alloy
rollers
Two, 17.5 dia. (length: 7)
stainless sintered alloy
rollers
M5 (length: 16)
Allen-head bolt
38R
38R
38R
M5 (length: 16)
Allen-head bolt
M5 (length: 16)
Allen-head bolt
Loosen the M5
×
12 bolt, set the
actuator's position and then tighten
the bolt again.
Loosen the screws.
Head
Head
Loosen
the
screws.