Two-circuit Limit Switch
WL
F-69
Lim
it
Switch
es
Specifications
■
Approved Standards
Note:
Contact your OMRON representative for more information on approved models.
■
Approved Standard Ratings
General-purpose Models
UL/CSA
Standard Models: A600
Microload Models:
0.1 A at 125 VAC, 0.1 A at 30 VDC
TÜV (EN60947-5-1)
(Only Ground Terminal Models are Approved)
Note:
As an example, AC-15 2 A/250 V means the following:
Spatter-prevention Models
UL/CSA
LE (Neon Lamp) A300
LD (LED)
Agency
Standard
File No.
UL
UL508
E76675
CSA
CSA C22.2 No. 14
LR45746
TÜV Rheinland
EN60947-5-1
R9551016
Rated voltage
Carry current
Current
Volt-amperes
Make
Break
Make
Break
120 VAC
10 A
60 A
6 A
7,200 VA
720 VA
240 VAC
30 A
3 A
480 VAC
15 A
1.5 A
600 VAC
12 A
1.2 A
Model
Category/rating
Thermal
current
Indicator
WL
@
-
@
AC-15 2 A/250 V
DC12 2 A/48 V
10 A
---
WL01
@
AC-14 0.1 A/125 V
DC12 0.1 A/48 V
0.5 A
---
WL
@
-LE
AC-15 2 A/250 V
10 A
Neon lamp
WL01
@
-LE
AC-14 0.1 A/125 V
0.5 A
Neon lamp
WL
@
-LD
AC-15 2 A/115 V
DC12 2 A/48 V
10 A
LED
WL01
@
-LD
AC-14 0.1 A/115 V
DC12 0.1 A/48 V
0.5 A
LED
Application category
AC-15
Rated operating current (Ie)
2 A
Rated operating voltage (Ue)
250 V
Rated
voltage
Carry
current
Current
Volt-amperes
Make
Break
Make
Break
120 VAC
10 A
60 A
6 A
7,200 VA
720 VA
240 VAC
30 A
3 A
Rated voltage
Carry current
115 VAC
10 A
115 VDC
0.8 A