4-29
Chapter 4. Advanced Setup
4
Advanced
Setup
(6) Check if communication is available between PC and PLC.Test the
roaming in the opposite direction and verify that access points should be
switched from AP-2 to AP-1 and that communication should be available
between PC and PLC.
CL-1
CL-1
(5) From CL-1 Setup screen "Information" menu, "Wireless information",
"BSSID", verify that BSSID should be AP-2 value.
Step 8. Checking PC-PLC Communication
Execute the Ping command to PLC from PC connected to AP-1 and verify its response.
(1) Execute a ping command from your PC at command prompt.
Example:Ping 192.168.0.10 (Partner's IP address)
C:¥>ping 192.168.0.10
Pinging 192.168.0.10 with 32 bytes of data:
Reply from 192.168.0.10: bytes=32 time<1ms TTL=250
*
If no response is returned, follow the steps below:
•
Execute "arp -d" command.
•
Verify if security settings are the same.
Click
If the client has different SSID and/or encryp-
tion setup from the access point, "Communi-
cation Unavailable" is displayed.
Содержание WE70-AP
Страница 1: ...OPERATION MANUAL WE70 AP CL pan FA Wireless LAN Unit Cat No N153 E1 01...
Страница 2: ......
Страница 32: ...Chapter 1 Overview 1 12 1 Overview...
Страница 98: ...Chapter 4 Advanced Setup 4 30 4 Advanced Setup...
Страница 146: ......