Communications Commands and Responses
Section 5-3
5-26
2)
Stop (ST)
This command causes the Controller in auto mode, repeat mode, FIFO Access, or Selective
Access to cancel the processing of communications when this command is received by the
Controller. The Controller then waits for the next command.
Command Frame Structure
STX Node No. Command
code
“ST”
ETX BCC
1
2
2
1
1
Response Frame Structure
STX
Node No. Retry
flag
Command
code
“ST”
Response
code
“00”
ETX BCC
1
2
1
2
2
1
1
Response code
00 : Normal completion
For other response codes, refer to 5-10 Response Code List.
3)
Reset (XZ)
This command software-resets the Controller.
Command Frame Structure
STX
Node No. Command
code
“XZ”
ETX BCC
1
2
2
1
1
4)
Controller Control command (CC)
This command is used for reading the user input terminal status.
Command Frame Structure
STX
Node No. Command
code
“CC”
ETX BCC
1
2
2
1
1
Response Frame Structure
STX
Node No. Retry
flag
Command
code
“IC”
Response
code
“00”
Input
Status
IN1
Input
Status
IN2
ETX BCC
1
2
1
2
2
1
1
1
1
Response code
00 : Normal completion
For other response codes, refer to 5-10 Response Code List.
Input status 1,2
1:ON, 0:OFF