Communications Phase
Section 5-8
5-45
5-8
Communications Phase
The following commands and responses can be made by specifying different command communi-
cations settings.
(1)
No Response
When the Controller receives the Reset Command, it is reset without returning a response and
waits for the next command.
Host
Controller
Command
Reset
(2)
1-to-1
One response is sent per command with the following commands: Single Trigger, Single Auto, FIFO
Trigger, FIFO Auto (commands that communicate with Tags) or commands that do not communicate
with Tags.
Host
Controller
Command
Response
(3)
Multiple Response
Multiple responses are sent per command when the following commands have been specified: Sin-
gle Repeat, FIFO Repeat, Multi-trigger, Multi-repeat, or Selective Access (for commands that com-
municate with Tags).
Host
Controller
Response
Command
Response
Response