5-6 Communication Command
5-11
5-6-2 Write (WT)
Writes the specified bytes of data from the specified first address into a tag.
Example: Writing 4 bytes of data ("11223344") from the address 0010h
(Single trigger, hexadecimal code)
Sent data: WTSTH 1 0 0 1 0 0 4 1 1 2 2 3 3 4 4 * [CR]
Received data: WT 0 0 0 0 * [CR]
Communication designation
Specifies how to communicate with a tag. For details, refer to the communication desig-
nation list.
Data designation
Specifies a type of transmitted code of data written into a tag.
"A": ASCII code
"H": Hexadecimal code
Antenna designation
Fixed to "1".
First address of written area
Specifies the first address of area, where data is written into, in four hexadecimal digits.
Available designation range: 0000h to 007Fh.
Number of written bytes
Specifies the number of bytes of data written into a tag in two hexadecimal digits.
Available designation range: 01h to 80h.
Written data
Data written into a tag. For a hexadecimal code, two characters per byte.
Correct Usage
Specify the number of written bytes so that the sum of the number of written bytes and the first address of written area
cannot exceed the tag memory capacity (128 bytes).
Example: For the address 0010h, the range between 00h and 70h can be specified.
<Command>
Command
code
"WT"
Communication
designation
Data
desig-
nation
Antenna
desig-
nation
The first address of written area
The number of
written bytes
Written data
Number of specified bytes
<Response>
Command
code
"WT"
Termination
code
"00"
Retrans-
mission
flag
Status
flag
Содержание V670 Series
Страница 1: ...USER S MANUAL Electromagnetic Inductive RFID System V670 Series Cat No Z148 E1 05...
Страница 14: ......
Страница 18: ...1 4...
Страница 40: ...2 22...
Страница 60: ...3 20...
Страница 72: ...4 12...
Страница 102: ...6 4...
Страница 104: ...7 2 Unit mm 7 2 Outside Dimension...
Страница 122: ...7 20...
Страница 142: ......