5-24
The meanings of termination code of response are described below.
Type
Termination Code
Name
Description
Normal end
"00"
Normal end
Command execution has ended correctly. A command
was executed correctly when polling process is speci-
fied.
Host commu-
nication
error
"10"
Parity error
A parity error has occurred in any character of com-
mand.
"11"
Framing error
A framing error has occurred in any character of com-
mand.
"12"
Overrun error
An overrun error has occurred in any character of com-
mand.
"13"
FCS error
FCS of received command is invalid.
"14"
Format error
A command format is incorrect. Character interval has
exceeded a preset time.
"15"
Execution status error
Communication designation is SI/RI/PI when input set-
ting is RESET. The "MO" command was executed
when no operating condition is registered.
"18"
Frame length error
A command string more than 300 characters was
received.
Tag communi-
cation error
"70"
Communication error
An error has occurred during the communication with a
tag and the communication cannot be completed cor-
rectly.
"71"
Verification error
A correct data cannot be written into a tag (only when
verification is enabled).
"72"
No-tag error
There is no tag in a communication area of antenna
when a trigger system command is executed. In a com-
mand which performed communication designation of
"st", there is no tag, which communicated immediately
before, in a communication area of antenna. The
antenna is not connected.
"74"
Outstanding tag error
In polling query, a communication process has not yet
been completed.
"7A"
Address designation
error
Designation of process address is unsuitable and the
execution is impossible.
"7D"
Write protect error
Something was written into a write-protected page.
"7E"
ID system error (1)
A tag cannot execute a command process.
"7F"
ID system error (2)
An inapplicable tag was used.
System error
"7C"
Antenna section error
No communication can be executed due to antenna
trouble.
"9A"
EEPROM error
An error in writing into/reading from nonvolatile memory
in the controller (the SP/SE command). The "MO" com-
mand was executed under invalid operating condition.
5-10 Termination Code List
Содержание V670 Series
Страница 1: ...USER S MANUAL Electromagnetic Inductive RFID System V670 Series Cat No Z148 E1 05...
Страница 14: ......
Страница 18: ...1 4...
Страница 40: ...2 22...
Страница 60: ...3 20...
Страница 72: ...4 12...
Страница 102: ...6 4...
Страница 104: ...7 2 Unit mm 7 2 Outside Dimension...
Страница 122: ...7 20...
Страница 142: ......