2-1 Controller
2-2
No.
Name
Function
Description
(1)
Note number setup switch
Sets a controller node
number.
Used to identify the controllers when a maximum of 31
controllers are connected to one host computer.
(2)
Dip switch
Sets every mode.
Sets an input function, operation mode, protocol, com-
munication conditions, etc.
(3)
LED display
An operation status is shown on this LED displayed.
RUN
Green
Shows the RUN sta-
tus.
Turns on when an operation is normal.
COMM
Green
Shows an operation
status.
Turns on during the communication to a tag.
NORM/ERR
Green
Shows the end of
communication.
Turns on once and turns off when the communication has
ended correctly.
Red
Shows an error.
Turns on once and turns off when the communication has
ended due to an error. Turns on when a system error
occurs.
RST/IN
Green
Shows an input status.
Turns on when the RST/IN input signal turns ON.
OUT1
Green
Shows an output status.
Turns on when the OUT1 output signal turns ON.
OUT2
Green
Shows an output status.
Turns on when the OUT2 output signal turns ON.
(4)
Cover
Cover common to (1), (2) and (5).
Open as necessary.
(5)
Connecting port for pro-
gramming console
Used to connect a
programming con-
sole.
Our programming console type C200H-PRO27 (unbun-
dled) can connect to this port through the connecting
cable model V700-P10 (unbundled). When you operate
the programming console, use the key sheet that comes
with the V700-P10.
(6)
Connecting port for antenna
Used to connect an
antenna.
One antenna can connect to this port. To extend the
cable, use model V670-A4
(unbundled).
(7)
RS-232C port
Used to connect a
host device.
Based on the RS-232C, a general-purpose programma-
ble controller (PLC) and PC can connect to this port.
(8)
Power supply terminal
Terminal for power supply.
24 VDC+
Supplies the power.
Connects the "+" side of 24 VDC power supply.
24 VDC-
Connects 0 V.
GR
Ground Class D (Class III).
(9)
Input terminal
Terminal for input.
RST/IN
Supplies a reset sig-
nal or trigger signal.
When external reset input and external trigger input are
used, they connects to this terminal together with 24
VDC- in pairs. Function can be selected with a dip
switch.
(10)
Output terminal
Terminal for output.
OUT1
Output signal 1
When external output is used, it connects to this terminal
together with O.COM in pairs.
OUT2
Output signal 2
O.COM
Output common
Содержание V670 Series
Страница 1: ...USER S MANUAL Electromagnetic Inductive RFID System V670 Series Cat No Z148 E1 05...
Страница 14: ......
Страница 18: ...1 4...
Страница 40: ...2 22...
Страница 60: ...3 20...
Страница 72: ...4 12...
Страница 102: ...6 4...
Страница 104: ...7 2 Unit mm 7 2 Outside Dimension...
Страница 122: ...7 20...
Страница 142: ......