Section 5
Communications
■
Frame Division
Divided the command into frames as shown below if the command is longer than 271 characters.
Frame Division
1. Divide the command so that each frame is 271 characters or less.
2. Attach a terminator (*CR) to the last frame (frame n). Attach a delimiter (CR) to all other frames.
3. The first frame (frame 1) must contain the command code, data code specification, Read/Write Head
and channel specifications, and the start address. If any of these are missing, a command input error
will occur. The write data does not have to be contained in the first frame.
4. Divide the command so that no frame contains “AA*CR” or “XZ*CR”.
CR
CR
CR
*CR
A/H
1/2
:
:
XW
Frame 1
1 frame = 271 characters max.
Start address
Write data 1
*CR
00
XW
Frame 2
Write data 2
Frame n-1
Write data n-1
Frame n
Write data n
CR
CR
CR
CR
:
Host device
ID Controller
Содержание V600 Series
Страница 1: ...RFID System V600 Series User s Manual Man No Z239 E1 03A ID Controller V600 CA5D01 V600 CA5D02 ...
Страница 22: ...20 Section 1 Overall Flow of Application RFID System Operation Manual Section 1 Product Overview MEMO ...
Страница 50: ...48 Section 2 Wiring RFID System Operation Manual Section 2 Installation and Wiring MEMO ...
Страница 72: ...70 Section 4 Write Command Memory RFID System Operation Manual Section 4 Function ...
Страница 138: ...136 Section 5 End Codes RFID System Operation Manual Section 5 Communications MEMO ...
Страница 150: ...148 Section 6 Troubleshooting Flowcharts RFID System Operation Manual Section 6 Troubleshooting MEMO ...