124
Se
ct
io
n 5
Gene
ral Commun
ic
a
tio
n
s
Subc
ommands
RFID System
Operation Manual
Section 5
Communications
ABORT (XZ)
If the ID Controller does not return a response due to a problem during host communications or during
communications with a Data Carrier, the ABORT command can be executed to restore the ID
Controller to the Command Wait Status.
No response will be returned to the ABORT command.
■
1:1 Communications
The ID Controller requires about 100 ms before it can receive the next command after it receives the ABORT command.
■
1:N Communications
The ID Controller requires about 100 ms before it can receive the next command after it receives the ABORT command.
Command
Command code
X
Z
2
2
*
CR
Terminator
Command
Command code
x
Z
2
2
*
CR
Terminator
2
x
x
FCS
3
Controller No.
x
@
x