WRITE PROCESSING REPEAT (RP)
WRITE PROCESSING REPEAT executes the most recently executed Write Command.
■
1:1 Communications
Write Command information is cleared under the following condition.
If the ID Controller's power supply is reset
A command input error will occur if WRITE REPEAT is executed under this condition.
Command code
The command code of the most recently executed Write Command.
End code
Indicates the results of command execution.
00: Normal end
Refer to
for more information.
Command
Command code
R
P
2
2
*
CR
Terminator
Response
Command code
x
x
0
0
2
2
2
*
CR
Terminator
End code