12
Wiring Controller Power and Ground
Section 2-3
2-3-3
Wiring the Power Supply
!Caution
Use a DC power supply with safe extra low-voltage circuits on the
secondary side. Excessively high voltages can result in electric
shock.
Power
supply
Use a power supply with the following specifications. We recommend
using OMRON’s S82K-01524 Power Supply.
Use a power supply with the following specifications when connecting
the V530-C300E and F150-M05L LCD Monitor to one power supply.
We recommend using OMRON’s S82K-05024 Power Supply.
Note
1.
Wire the Power Supply Unit independently of other devices. In
particular, keep the power supply wired separately from inductive
loads.
2.
Keep the power supply cable as short as possible (max.: 10 m).
3.
If UL recognition is required, use a UL class II power supply.
Output current
0.6 A min.
Power supply voltage
24 VDC+10%, –15%
Output current
1.6 A min.
Power supply voltage
24 VDC+10%, –15%
24VDC
PWR
RUN
ERR
RS-232C
SCANNER
MONITOR
CONSOLE
2D CODE READER
V530-C300
1
2
3
4
5
6
O
N
TRIG
24 VDC
+
−