98
SET (Setting) Mode
Section 5-1
Procedure
1,2,3...
1.
Select 2. Image Analysis and press the ENT Key.
2.
Select either Line Bright X or Line Bright Y as required and
press the ENT Key.
3.
Select the gray edge level for black and white judgment.
(1 to 255)
Press the ENT Key to change the cursor to fill one digit or charac-
ter. Use the Left/Right Keys to change line and use the Up/Down
Keys to change the gray edge level.
4.
Select Register. The Line Bright screen will be displayed.
5.
Move the cross cursor with the Up/Down/Left/Right Keys and
press the ENT Key when the cursor is at the beginning point of
the required line. Press the SHIFT Key together with the above
keys to move the cursor faster.
6.
Move the cross cursor with the Up/Down/Left/Right Keys and
press the ENT Key when the cursor is at the end point of the re-
quired line.
1. Read DM (Normal)
2. Image Analysis
0. Image Adjust
Analyse input image.
Display Pixel Value
Contrast (Line Bright)
Hardware Check
Image Magnifier
Measure Length
Contrast (Region)
Gray Edge Value [32]
Register
Cancel