Appendix E
Configurator Error and Warning Messages
E-1
Warning Messages
The table below lists the Warning messages which can be displayed by the PROFIBUS-DP Master Unit DTM.
These messages usually indicate that the user is about to perform an action, which will have significant impact,
or an action which is only partly supported by the Unit. The User is given a chance to abort the function if the
impact is undesirable.
Number
Message
Description
When occurring
00
Change the PLC to PROGRAM
mode?
In order to start downloading a configuration, the
PLC must be set to PROGRAM mode, to prevent
I/O data being exchanged with the Unit, during
the change of the configuration.
•
Yes
Change state and download configu-
ration.
•
No
Stop download.
At the start of download-
ing, in case the PLC is in
RUN/MONITOR mode.
01
DPV1 Slave/slaves is assigned to
master. DPV1 slaves are not fully
supported.
The PROFIBUS-DP Master Unit supports only
basic DPV0 functions. This means that the DPV1
slave can still be operated, but the DPV1 func-
tionality is not possible:
•
OK
Close message box.
At the start of download-
ing, in case one of the
slaves is a DPV1 slave.
02
Return the PLC to [mode] mode?
After download with PLC previously in RUN or
MONITOR the PLC can be returned to RUN or
MONITOR mode
•
Yes
Change state.
•
No
PLC remains in PROGRAM mode.
•
Cancel PLC remains in PROGRAM mode.
After completing the
download.
03
PROFIBUS I/O Data "area over-
lapping" and/or "exceeding mem-
ory range" Save anyway?
One or more of the I/O Data mappings is incor-
rect. Either the I/O data or a part of the I/O data
is mapped beyond an existing memory area, or
two or more mappings are overlapping in mem-
ory.
•
Yes
Save settings.
•
No
Do not save settings.
•
Cancel Do not save settings.
Closing the Configura-
tion User Interface with
invalid configuration or
saving invalid settings
04
Settings have been changed.
Would you like to save?
One or more settings have been changed, but
not yet saved.
•
Yes
Save data and close DTM.
•
No
Do not save data and close DTM.
•
Cancel Do not close the DTM.
Closing the Configura-
tion User Interface with-
out saving the changes.
05
Settings have been changed.
Would you like to leave without
saving?
Closing the GUI without saving the configuration.
•
Yes
Do not save data and close DTM.
•
No
Do not save data and do not close
DTM.
Closing the Configura-
tion User Interface with-
out saving the changes.
06
Compressing will re-allocate slave
configuration in [memory area].
Continue?
Note
[Memory Area] = Input
Area 1/ Input Area 2/ Out-
put Area 1/ Output Area 2
Each of the slave I/O data mapping areas can be
compressed, by pressing the Compress button.
This will result in the DTM filling up all the gaps in
the mapping, by moving I/O data from higher
addresses closer to the start address of the map-
ping area.
•
Yes
Compress memory area.
•
No
Do nothing.
When pressing the
Compress button in the
Slave Area tab, I/O Allo-
cation.
Содержание SYSMAC CJ1W-PRM21
Страница 2: ...iv...
Страница 36: ...22 Basic Operating Procedure Section 1 5...
Страница 52: ...38 Defining PROFIBUS DP in the Software Section 2 5...
Страница 112: ...98 Allocated CIO Area Words Section 4 2...
Страница 122: ...108 Command Response Reference Section 5 2...
Страница 160: ...146 Replacing the Unit Section 7 8...
Страница 174: ...160 Appendix...
Страница 180: ...166 I O Data Conversions Appendix D...
Страница 186: ...172 Configurator Error and Warning Messages Appendix E...
Страница 187: ...173 Index...
Страница 188: ...174 Index...
Страница 190: ...176 Revision History...