69
Example 3:
In the following program, phrases are registered in the read-only DM area
(DMs 1000 through 1999).
Register the following data in the DM area (starting from DM 1000) via the
Programming Console:
Phrase Combination
Number of playback
combinations
Repeat
interval
Phase no. 1
no. 3 + no. 10 + no. 22
5 times
2.0 s
Phase no. 2
no. 12 + no. 46 + no. 35 + no. 50
2 times
1.5 s
The DM area is to be assigned as follows:
0205
DM no.
DM 1000
DM 1001
DM 1002
DM 1003
DM 1004
DM 1005
DM 1006
Data
0310
2200
0152
1246
3550
0000
Contents
Repeat intervals and number of repetitions
Phrases nos. 3 and 10
Phrase no. 22 and the message end code (00)
Repeat intervals and number of repetitions
Phrases nos. 12 and 46
Phrases nos. 35 and 50
End code (00)
Message
no. 1
Message
no. 2
Program
When input 00100 turns ON, Message no. 1 is played back.
When input 00101 turns ON, Message no. 2 is played back.
@ XFER
#0003
120
12014
00100
03000
03001
DM1000
DIFU
03000
@ XFER
#0004
120
00101
DM1003
DIFU
03001
This command transfers the data of DM
1000 through DM 1002 to the Voice
Unit (when input 00100 turns ON).
This command transfers the data of DM
1003 through DM 1006 to the Voice
Unit (when input 00101 turns ON).
This command issues the output
command.
Phrase Combination Mode Example Programs
Section 4-2