Continued from previous page.
00000FM MEMIOM
START BLOCK 1000
00000FM MEMIOM
XFER G
00000FM MEMIOM
XFER END 1011
00000FM MEMIOM
XFER HALTED 1005
Aborting during operation
Changing numbers
7-3-5
File Memory Edit
The File Memory Edit operation allows you to read and modify data stored in
the FM area (IOM). Data can be read in RUN mode with this function, but it
can be modified only when in MONITOR or PROGRAM mode.
If you do not specify a start block, the reading will begin at the first block of
the FM area. To access words within the current block, use the up and down
keys to scroll through word-by-word, or to go directly to a specific word within
the block by entering CLR, the word number, then the down key.
To change the contents of an FM area word, enter the new data for the cur-
rent word, followed by WRITE. This will write the data into the FM area word.
Program and comment data stored in the FM area cannot be rewritten with
this operation.
Key Sequence
[ Start block ]
[ Programming
operations ]
File Memory Operations
Section 7-3