No. 17
ON
ON
ON
Normal rotation 1
Frequency
Jog signal
Forward run rotation signal
Reverse run rotation signal
Time
Reverse rotation
2-10-6 Accel/Decel Time and Patterns
Item name
Constant to be set
Factory preset
Acceleration time 1
No. 9
10.0 s
Deceleration time 1
No. 10
10.0 s
Acceleration time 2
No. 11
10.0 s
Deceleration time 2
No. 12
10.0 s
Each item can be set from 0.0 sec to 600.0 sec.
The set time indicates the interval required before the maximum
output frequency No. 2 is reached.
Time marked with
A
can be set for two-step switching using an ex-
ternal contact.
No. 2
No. 9
No. 12
No. 11
Output frequency
No. 10
Open: No. 9 and 10 are selected.
Closed: No. 11 and 12 are selected.
Time
Out
put
fr
equenc
y
2-10-7 Output Frequency Control (Gain/Bias)
Item name
Constant to be set
Factory preset
Frequency command gain
No. 22
1.0
Frequency command bias
No. 23
0.00
Output frequency (gain/bias) can be set freely according to fre-
quency setting (0 to 10 V or 4 to 20 mA)
No. 22
0
100%
No. 23
10 V
(4 mA)
(20 mA)
Bias
(100% = 1.00)
Limit value
Frequency setting
Gain
Section 2-10