72
Chapter
4
Wiring Examp
le
s
F3SJ-B
User’s Manual
Input/Output Circuit and Applications
Connecting a F3SJ-B to Various Controllers
Connecting a F3SJ-B to an F3SP-B1P
•Connector can reduce wiring time
•Safety relay included
PLC
IN1
IN2
OUT
S1
S2
A1
H1
L1
J1
H1
X1
P1
13
23
33
41
KM3
KM1
KM2
Test
Reset
Auxiliary
output
Safety
output 1
Safety
output 2
K1
K2
K1
K2
A2
PE
T31
T32
External device
monitoring
14
24
34
42
KM1
KM2
KM1
KM2
F3SP-B1P
Power
supply
+24 VDC
0 V
- Using external device monitoring function
S1 : External test switch
S2 : Lockout reset switch
KM1, KM2 : Safety relay with force-guided contact (G7SA)
or magnetic contactor
KM3 : Solid state contactor (G3J)
M : 3-phase motor
PLC : Programmable controller
(Used for monitoring -- not related to safety system)
M
T32
T31
Wiring when not using external device monitoring function
External device
monitoring
Standard short-circuit bar
Feedback loop
Receiver
Emitter
F39-JD
B-L
F39-JD
B-D
+24 V
Unblocked
Blocked
External test switch (S1)
Reset switch (S2)
Safety output
K1,K2 N.O. contact
KM1,KM2 N.O. contact
K1,K2 N.C. contact
KM1,KM2 N.C. contact
PLC input 1
PLC input 2
PLC output
Lockout
state
Содержание Sti F3SJ-B P25-01TS Series
Страница 1: ...F3SJ B P25 01TS Series Safety Light Curtain User s Manual Cat No SCHG 734C ...
Страница 12: ...x Introduction F3SJ B User s Manual ...
Страница 82: ...68 Chapter 3 Wiring F3SJ B User s Manual Wiring Installation ...
Страница 92: ...78 Chapter 4 Wiring Examples F3SJ B User s Manual Input Output Circuit and Applications ...
Страница 98: ...84 Chapter 5 Maintenance Checklists F3SJ B User s Manual Checklists ...