5
F3SJ-B
User’s Manual
Chapter
1
In
ter
nal (LED) Indica
tor
Display
Pa
tt
ern
Overview and Specifications
E
Emitter
Receiver
* It turns ON when there is an external device monitoring input regardless of the availability of the external device monitoring.
No.
Internal indicator
ON
Blinking
1
Top-beam-state indicator
TOP
Turns ON when the top beam is receiving
light.
Blinks when cap error or connection error
occurs.
2
Stable-state indicator
STB
Turns ON when incidence level is 170% or
more of the output ON threshold.
Blinks when the safety output is turned
OFF due to disturbance light or vibration.
3
ON/OFF-state indicator
ON
OFF
Green: Turns ON when safety output is
ON.
Red: Turns ON when safety output is OFF.
Red: Blinks when the F3SJ-B enters a
lockout due to a safety output error.
4
Lockout indicator
LOCKOUT
Turns ON when the F3SJ-B enters a
lockout on the receiver.
Blinks when the F3SJ-B enters a lockout
on the emitter.
5
Power indicator
POWER
Turns ON while the power of the emitter is
ON.
Blinks when the F3SJ-B enters a lockout
due to power voltage/noise.
6
Test indicator
TEST
–
Blinks when external test is being
performed.
10 Bottom-beam-state indicator BTM
Turns ON when the bottom beam is
receiving light.
–
No.
Internal indicator
ON
Blinking
1
Top-beam-state indicator
TOP
Turns ON when the top beam is receiving
light.
Blinks when cap error or connection error
occurs.
2
Stable-state indicator
STB
Turns ON when incidence level is 170%
or more of the output ON threshold.
Blinks when the safety output is turned
OFF due to disturbance light or vibration.
3
ON/OFF-state indicator
ON
OFF
Green: Turns ON when safety output is
ON.
Red: Turns ON when safety output is
OFF.
Red: Blinks when the F3SJ-B enters a
lockout due to a safety output error.
4
Lockout indicator
LOCKOUT
Turns ON when the F3SJ-B enters a
lockout on the emitter.
Blinks when the F3SJ-B enters a lockout
on the receiver.
5
Communication indicator
COM
Turns ON when communication between
emitter and receiver is established.
Blinks when the F3SJ-B enters lockout
due to a communication error between
receiver and emitter.
6
Configuration indicator
CFG
–
Blinks when the F3SJ-B enters lockout
due to a model type error between
receiver and emitter.
7
Internal error indicator
INTERNAL –
Blinks when the F3SJ-B enters a lockout
due to an internal error.
8
Interlock indicator
INT
-LK
Not used
Not used
9
External device monitoring
indicator
EDM
Turns ON when an input is given to
external device monitoring input. *
Blinks when the F3SJ-B enters a lockout
due to an external device monitoring
error.
10 Bottom-beam-state indicator BTM
Turns ON when the bottom beam is
receiving light.
–
Содержание Sti F3SJ-B P25-01TS Series
Страница 1: ...F3SJ B P25 01TS Series Safety Light Curtain User s Manual Cat No SCHG 734C ...
Страница 12: ...x Introduction F3SJ B User s Manual ...
Страница 82: ...68 Chapter 3 Wiring F3SJ B User s Manual Wiring Installation ...
Страница 92: ...78 Chapter 4 Wiring Examples F3SJ B User s Manual Input Output Circuit and Applications ...
Страница 98: ...84 Chapter 5 Maintenance Checklists F3SJ B User s Manual Checklists ...