28
Ch
apt
e
r
3
Dimen
s
ions
F3SJ-B
User’s Manual
Wiring/Installation
Side mounting
Bracket mounting procedure (Mounting) p.47
- If the protective height is more than 1105 mm, use Intermediate Brackets of specified quantities and locations
according to the dimensions. If the brackets described above are not used, ratings and performance cannot be met.
- When you use a sensor in a situation where the sensor is under a load, add an Intermediate Bracket.
12
34.5
Top/Bottom Bracket
(F39-LJB1)
Top/Bottom Bracket
(F39-LJB1)
Intermediate Bracket
(F39-LJB2)
E
[ Unit : mm ]
13.4
34
42
53
42
5.5
30
7
18.3
dia.9
30
19
6.5
7.5
B
A
22.5
D
C (Protective height)
16
46
30
45
<M5 screw fixed>
<M8 screw fixed>
19
B
B
E
C
C
E
42
42
5.9
5.9
22
22
4-M5
2-M8
2-M5
2-M5
Dimensions A to E
Dimensions E
* Value E must be 700 mm or less when not using value E obtained from the calculation above.
A
C+69
B
C+42.2
C
4-digit number of the type name (protective height)
D
C-45
E
Depends on the protective height. See the table below.
Protective height
Number of Intermediate Brackets
Dimensions E
0185 to 1105
0
-
1185 to 1345
1
C/2 max.
1425 to 2065
2
C/3 max.
Содержание Sti F3SJ-B P25-01TS Series
Страница 1: ...F3SJ B P25 01TS Series Safety Light Curtain User s Manual Cat No SCHG 734C ...
Страница 12: ...x Introduction F3SJ B User s Manual ...
Страница 82: ...68 Chapter 3 Wiring F3SJ B User s Manual Wiring Installation ...
Страница 92: ...78 Chapter 4 Wiring Examples F3SJ B User s Manual Input Output Circuit and Applications ...
Страница 98: ...84 Chapter 5 Maintenance Checklists F3SJ B User s Manual Checklists ...