Overview and Specifications
E
Item
Model
F3SJ-B
P25-01TS
Protection circuit
Output short-circuit protection, and power supply reverse polarity protection
Ambient temperature
During operation: -10 to 55°C (non-freezing), During storage: -25 to 70°C
Ambient humidity
During operation: 35 to 85%RH (non-condensing), During storage: 35 to 95%RH
Ambient light intensity
Incandescent lamp: 3,000 lx max. on receiving surface. Sunlight: 10,000 lx max. on
receiving surface.
Insulation resistance
20 M
Ω
or higher (500 VDC)
Dielectric strength
1,000 VAC, 50/60 Hz, 1 min
Degree of protection
IP65 (IEC 60529)
Vibration resistance
Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps each in X, Y, and Z
directions
Shock resistance
Malfunction: 100 m/s
2
, 1,000 times each in X, Y, and Z directions
Pollution degree
Pollution degree 3 (IEC 60664-1)
Power cable
Connection
method
Prewired connector cable, cable length 0.3 m
Connector type (M12, 8-pin)
Connector: IP67 rated (when mated)
Number of wires 8 wires
Cable diameter Dia. 6 mm
Allowable
bending radius
R5 mm
Series connection cable
(F39-JBR2W)
Connection
method
Prewired connector cable, cable length 0.2 m
Connector type (M12, 8-pin)
Connector: IP67 rated (when mated)
Number of wires 8 wires
Cable diameter Dia. 6 mm
Allowable
bending radius
R5 mm
Extension cable
(F39-JD
A, JD
B)
Connection
method
Connector method (M12, 8-pin)
IP67 degree of protection for connector (fitting)
For details about twisted pair wires (single-ended cable) p.64, (double-ended
cable) p.65
For details about total extension cable length
Number of wires 8 wires
Cable diameter Dia. 6.6 mm
Allowable
bending radius
R36 mm
Extension cable
30 m max.
Material
Case: Aluminum
Cap: ABS resin, PBT
Optical cover: PMMA resin (acrylic)
Cable: Oil resistant PVC
Weight (packaged)
Weight (g) = (protective height) x 2.7 + 500
Accessories
CD (User's Manual), Instruction mannual
Applicable standards
Refer to "Legislation and Standards" on page i.
Safety-related characteristic data
(EN 61508:2010)
See http://www.fa.omron.co.jp/safety_6en/
Содержание Sti F3SJ-B P25-01TS Series
Страница 1: ...F3SJ B P25 01TS Series Safety Light Curtain User s Manual Cat No SCHG 734C ...
Страница 12: ...x Introduction F3SJ B User s Manual ...
Страница 82: ...68 Chapter 3 Wiring F3SJ B User s Manual Wiring Installation ...
Страница 92: ...78 Chapter 4 Wiring Examples F3SJ B User s Manual Input Output Circuit and Applications ...
Страница 98: ...84 Chapter 5 Maintenance Checklists F3SJ B User s Manual Checklists ...