6
List of Available Units
Section 1-4
1-4
List of Available Units
The following table shows the Units that can be used in Slice I/O Terminals as
well as the devices that can be connected. Refer to the
GRT1 Series Slice I/O
Units Operation Manual
for details, such as Slice I/O Unit specifications.
Switches
Node-address
setting switches
Decimal rotary switches
Set the Unit’s node address as a DeviceNet Slave.
Other switches
DIP switch
Pin 1: Create/Enable registered table (Switch from
OFF to ON to register the table. Leave ON to enable
the table.)
Pin 2: Always OFF.
Pin 3: Automatic restore (Auto-restore enabled when
ON.)
Pin 4: Backup trigger (Switch from OFF to ON two
times to backup the parameter data.)
Connector
One open connector for DeviceNet, with screws
The XWG4-05C4-TF-D Multi-drop Connector can be
connected.
Terminals
Two terminals for I/O power supply
Two terminals for Unit power supply
Power consumption
3 W
Power consumption per block
80 W max. (Unit power supply)
(If more than 80 W is required, separate into blocks
using Turnback Units.)
Block separation
Basic block plus up to two other blocks
I/O current consumption
4 A max.
Weight
137 g
Accessories
XW4G-05C4-TF-D Connector
For multi-drop node connection. Connector screws
provided.
Item
Specification
Model
number
Specifications
GRT1-DRT
DeviceNet Communications Unit (Up to 64 I/O Units can be con-
nected.)
GRT1-ID4
Slice I/O Unit with 4 DC inputs (NPN)
GRT1-ID4-1
Slice I/O Unit with 4 DC inputs (PNP)
GRT1-OD4
Slice I/O Unit with 4 DC outputs (NPN)
GRT1-OD4-1 Slice I/O Unit with 4 DC outputs (PNP)
GRT1-ROS2
Slice I/O Unit with 2 relay outputs
GRT1-AD2
Slice I/O Unit with 2 analog inputs
GRT1-DA2V
Slice I/O Unit with 2 voltage analog outputs
GRT1-DA2C
Slice I/O Unit with 2 current analog outputs
GRT1-END
End Unit
GRT1-PD2
I/O Power Supply Unit
GRT1-TBR
Right Turnback Unit (Mounts to the right side of I/O Terminal.)
GRT1-TBL
Left Turnback Unit (Mounts to the left side of I/O Terminal.)
GCN2-100
Turnback Cable (1 m)
Содержание SMARTSLICE - 04-2008
Страница 1: ...DeviceNet Communications Unit Cat No W454 E1 03 SmartSlice GRT1 DRT OPERATION MANUAL ...
Страница 2: ...SmartSlice GRT1 DRT DeviceNet Communications Unit Operation Manual Revised April 2008 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 13: ...xiv ...
Страница 27: ...8 Basic Operating Procedure Section 1 5 ...
Страница 57: ...38 Unit Functions Section 2 3 ...
Страница 101: ...82 DeviceNet Explicit Messages Appendix A ...
Страница 113: ...94 Standard Models Appendix C ...
Страница 115: ...96 Power Consumption Tables Appendix D ...
Страница 117: ...98 I O Current Consumption Appendix E ...
Страница 119: ...100 Glossary ...