Display window for new sensor settings New settings of E3NT-L
Section 8-2
45
8-2-2-3-1
Pin assignments
The functions of
Connector pin 2
and
Connector pin 5
are set in the
Pin
Assignment
box.
In total, the sensor can be operated with a maximum of three inputs/outputs,
and a maximum of two outputs is possible at the same time.
The functions of the inputs/outputs can be set in the following order:
Connector pin 4
is always defined as
Output 1 (OUT1)
and cannot be modi-
fied.
Connector pin 2
can be set as
Switching output 2 (OUT2),
teaching input
(TEACH)
for the switching points A and C or as the
test input (TEST)
or
trig-
ger input (TRIG)
.
Connector pin 5
can be set as the
trigger input (TRIG)
,
teaching input
(TEACH)
for the switching points A to D or as the
test input (TEST
).
• Teaching input TEACH
If a signal in the operating voltage range (at least 10 V) is applied to this
input, the switching point A, B, C or D is teached, depending on the set-
tings, and analogously to the Teach buttons
(see Section 8-2-1-1 Teaching
switching points)
.
•
Test input TEST
The emitter is deactivated if a signal in the operating voltage range (at
least 10 V) is applied to this input.
If the sensor is in the light-on state, the receiver detects the absence of
the emitted light reflected by the measured object, regardless of the set-
ted switching points.
The output state changes.
This function can be used to test correct functioning of the sensor.
•
Trigger input TRIG
If a signal in the operating voltage range is applied to this input, the sen-
sor is requested to start a measurement (object distance).
The sensor rate (response time) can be increased by the trigger func-
tion.
•
Switching outputs OUT1 and OUT2
The switching outputs switch when a measured object is detected and in
accordance with the sensor's settings.
Содержание SENSOR SUPPORT SOFTWARE S3
Страница 1: ...OPERATION MANUAL Software Description SensorSupportSoftware S3 Cat No E31E EN 01 ...
Страница 2: ......
Страница 4: ...4 ...
Страница 9: ...9 SECTION 2 Safety notes 2 1 Safety notes 10 ...
Страница 11: ...11 SECTION 3 Program installation 3 1 Installation 12 3 2 Deinstallation 12 ...
Страница 13: ...13 SECTION 4 Connecting the sensor to the PC 4 1 Connecting the sensor to the PC 14 ...
Страница 15: ...15 SECTION 5 Program start 5 1 Starting the SensorSupportSoftware 16 ...
Страница 19: ...Starting the SensorSupportSoftware Section 5 1 19 E3NT R ...
Страница 20: ...20 Starting the SensorSupportSoftware Section 5 1 ...
Страница 21: ...21 SECTION 6 Program definitions 6 1 Program control keys 22 ...
Страница 24: ...24 Program control keys Section 6 1 ...