Display window for new sensor settings New settings of E3NT-L
Section 8-2
41
8-2-2-1-1
Function
The mode of the output is set in the
Function
box:
Background suppression BGS
(factory default)
The background suppression mode can be set separately for both
outputs.
Measured objects are detected as from the blind zone up to the set-
ted or teached switching point S
A
Objects in the background, behind
the setted or teached switching point S
A
, are ignored.
Foreground suppression FGS
The foreground suppression mode can be set separately for both
outputs.
Measured objects are detected as from the setted or teached
switching point S
A
up to the maximum sensing distance. Objects in
the foreground, between the sensor and the setted or teached
switching point S
A
, are ignored.
Window evaluation
The
window
evaluation mode can be set separately for both out-
puts.
Measured objects are only detected in the measurement window
between the two setted or teached switching points (switching
zone). Objects outside of this measurement window in the fore-
ground and in the background are ignored.
8-2-2-1-2
Switching inversion
Switching inversion of the output is set in the
Switching inversion
box. This
parameter can be set separately for both outputs.
Light-On
(factory default)
The output is active when
one
measured object is detected.
Dark-On
The output is active when
no
measured object is detected.
Содержание SENSOR SUPPORT SOFTWARE S3
Страница 1: ...OPERATION MANUAL Software Description SensorSupportSoftware S3 Cat No E31E EN 01 ...
Страница 2: ......
Страница 4: ...4 ...
Страница 9: ...9 SECTION 2 Safety notes 2 1 Safety notes 10 ...
Страница 11: ...11 SECTION 3 Program installation 3 1 Installation 12 3 2 Deinstallation 12 ...
Страница 13: ...13 SECTION 4 Connecting the sensor to the PC 4 1 Connecting the sensor to the PC 14 ...
Страница 15: ...15 SECTION 5 Program start 5 1 Starting the SensorSupportSoftware 16 ...
Страница 19: ...Starting the SensorSupportSoftware Section 5 1 19 E3NT R ...
Страница 20: ...20 Starting the SensorSupportSoftware Section 5 1 ...
Страница 21: ...21 SECTION 6 Program definitions 6 1 Program control keys 22 ...
Страница 24: ...24 Program control keys Section 6 1 ...