Refer to
UPS Power Attendant Lite for Windows User's Manual
for details.
5
Select
Detailed Setting / Other Settings / Communication Setting / UPS Communication
Port
to display the parameter
COM search to UPS detection
.
6
Set the parameter to
Do not search for COM ports
to prevent interference for the COM ports.
7
Select
Submit
to save the setting.
8
Select the close button in the right top corner to exit the Power Attendant Lite Utility software.
9
Select the restart behavior of the Box PC with the Bios Boot Menu parameter
Power Loss
Control
.
Set this parameter to
Turn On
to restart automatically after a power down from the Power At-
tendant Lite Utility.
Refer to the Bios Boot Menu information for details.
10
Test the UPS shutdown behavior.
(1) Start the Box PC
(2) Start applications
(3) Create a power interruption
(4) Monitor the shutdown sequence and confirm a correct shutdown
When the shutdown sequence is not correct change parameters in the Power Attendant
Lite Utility software and test the UPS shutdown behavior again.
The Power Attendant Lite Utility is configured.
The Box PC will shut down properly in case of a power supply interruption and restart automatically
when the power is restored.
3 Software
3 - 18
NY-series Industrial Box PC User's Manual (W553)
Содержание NYB17-11
Страница 30: ...Sections in this Manual 28 NY series Industrial Box PC User s Manual W553...
Страница 38: ...1 Overview 1 8 NY series Industrial Box PC User s Manual W553...
Страница 60: ...2 Hardware 2 22 NY series Industrial Box PC User s Manual W553...
Страница 218: ...7 Maintenance 7 42 NY series Industrial Box PC User s Manual W553...
Страница 239: ...I Index I 1 NY series Industrial Box PC User s Manual W553 I...
Страница 242: ......
Страница 243: ......