5-3-2
Product Orientation
The Box PC can be mounted in a book
A
or wall
B
C
orientation.
• For book mount there is one allowed orientation
A
.
• For wall mount there are two allowed orientations, horizontally mounted
B
and vertically mounted
C
.
Do not install the Box PC in other orientations.
A
C
Book mount
Frontview Sideview
Wall mount
Frontview
Horizontal
Frontview
Vertical
Sideview
B
5-3-3
Temperature
The temperature inside a control panel may be at least 10 to 15°C higher than outside the panel. Im-
plement the following measures against overheating at the installation site and in the control panel,
and allow a sufficient margin for the temperature.
Distance for Cooling
Adequate airflow around the Industrial Box PC is required.
Additional Information
• The ambient temperature must be within the operating range.
4-3-1 Operation Environment Specifications
on page 4 - 25 for temperature specifi-
cations.
• Allow space to accommodate for the bending radius of the cables.
Refer to:
•
•
2-9-6 USB Type-A to USB Type-B Cables
•
for cable bending requirements.
5 Installation
5 - 15
NY-series Industrial Box PC Without Operating System User's Manual (W586)
5-3 Mount
5
5-3-2 Product Orientation
Содержание NYB17-*100 SERIES
Страница 8: ...CONTENTS 6 NY series Industrial Box PC Without Operating System User s Manual W586...
Страница 30: ...Revision History 28 NY series Industrial Box PC Without Operating System User s Manual W586...
Страница 32: ...Sections in this Manual 30 NY series Industrial Box PC Without Operating System User s Manual W586...
Страница 40: ...1 Overview 1 8 NY series Industrial Box PC Without Operating System User s Manual W586...
Страница 68: ...3 Software 3 4 NY series Industrial Box PC Without Operating System User s Manual W586...
Страница 189: ...I Index I 1 NY series Industrial Box PC Without Operating System User s Manual W586 I...
Страница 192: ......
Страница 193: ......