XS5
19
•
Align the triangular marks on the pin block and cover and insert the
pin block into the cover.
•
Press them together firmly (0.39 to 0.49 N·m) until the pin block
does not come out of the cover.
(5) Mounting Cap
•
After mounting the cover to the pin block and the cover snaps into
place, tighten the cap securely by hand within a torque of 0.39 and
0.49 N·m.
Note:
If the cap is not tighten securely enough, the degree of
protection (IP67) may not be maintained or vibration may
cause the cap to become loose. Do not tighten the cap with
pliers or similar tools; they may damage the cap.
•
After fully tightening the cap, length A should be approximately one
of the following according to the cable external diameter and the
Connector model.
(6) After Assembly
•
Confirm the insulation between cores after completing assembly.
Recommended Cables
When connecting a commercially available cable to a connector
assembly, use a cable with an outside diameter of 3 to 6 mm and core
sizes of 0.18 to 0.75 mm
2
for crimping connectors and 0.5 mm
2
maximum for soldering connectors.
Connector Arrangement
For safety, when constructing a connection system between a Sensor
and panel with a connector, make sure that the connector plug is on
the Sensor side and the connector socket is on the panel side (i.e.,
the female pins are located on the power-supply side).
Connecting the XS5
1. Connecting the XS5 Plug and Socket
•
Align the projection on the plug cover with the polarity key on the
socket, then insert the plug all the way in.
•
Hold the knurled socket grip, then insert the projection on the plug
into the groove of the socket.
•
Turn the knurled grips of the socket clockwise approximately 45
degrees in respect to the plug. A click will indicate that the
Connectors are locked. The locking condition can also be
confirmed by the alignment marks on the plug and socket.
2. Connecting the XS5 and XS2
•
Align the projection on the plug cover with the polarity key on the
socket, then insert the plug all the way in.
•
In the same way as when connecting two XS2 Connectors, screw
the knurled grip in the clockwise direction.
•
Use your fingers to tighten the Connectors sufficiently.
Connector
Cable external diameter (mm)
6 mm
5 mm
4 mm
3 mm
For 6-mm-dia. cable
1
0
---
---
For 4-mm-dia. cable
---
2
1
---
For 3-mm-dia. cable
---
---
2
1
Triangle mark
Pin block
Cover lock
Pin Block
(Screw-mounting Connectors)
Cover
Cap
A
Sensor Side
Connecting Cable
Panel Side
(Power-supply Side)
(Plug)
(Socket)
(Plug)
(Socket)
Protrusion on
cover aligns with
polarity key.
Polarity key
Alignment marks
Содержание M12 -