K8DT-AS

11

1.

 Do not use or store the product in the following locations.

Locations subject to water, or oil

Outdoor locations or under direct sunlight

Locations subject to dust or corrosive gases (sulfurizing gases, 
ammonia gases, etc.)

Locations subject to rapid temperature changes

Locations prone to icing and dew condensation

Locations subject to vibration and large shocks

Locations subject to wind and rain

Locations subject to static electricity or noise

Locations subject to insects or small animals

2.

Use and store the product in a location where the ambient 
temperature and humidity are within the specified ranges. If 
applicable, provide forced cooling.

3.

Check terminal polarity and wire all terminals correctly. The power 
supply terminals, however, do not have polarity.

4.

Do not wire the input and output terminals incorrectly.

5.

Make sure the power supply voltage and loads are within the 
specifications and ratings for the product.

6.

Make sure the ferrule terminals for wiring are of the specified size.

7.

The stripping length is 8 mm. Insert the wires all the way to the 
back.

8.

Do not connect anything to terminals that are not being used.

9.

Use a power supply that will reach the rated voltage within 1 
second after the power is turned ON.

10.

Keep wiring separate from high voltages and power lines that draw 
large currents. Do not place product wiring in parallel with or in the 
same path as high-voltage or high-current lines.

11.

Do not install the product near equipment that generates high 
frequencies or surges.

12.

The product may cause incoming radio wave interference. Do not 
use the product near radio wave receivers.

13.

Install an external switch or circuit breaker and label it clearly so 
that the operator can quickly turn OFF the power supply.

14.

Make sure the indicators operate correctly. Depending on the 
application environment, the indicators may deteriorate 
prematurely and become difficult to see.

15.

Do not use the product if it is accidentally dropped. The internal 
components may be damaged.

16.

Be sure you understand the contents of this catalog and handle 
the product according to the instructions provided.

17.

Do not install the product in any way that would place a load on it.

18.

When discarding the product, properly dispose of it as industrial 
waste.

19.

When using the product, remember that the power supply 
terminals carry a high voltage.

20.

The product must be handled only by trained electrician.

21.

Prior to operation, check the wiring before you supply power to the 
product.

22.

Do not install the product immediately next to heat sources.

23.

Perform periodic maintenance.

24.

Do not wire anything to the release holes.

25.

When you insert a flat-blade screwdriver into a release hole, do not 
tilt or twist the screwdriver. The terminal block may be damaged.

26.

Insert a flat-blade screwdriver into the release holes at an angle. 
The terminal block may be damaged if the screwdriver is inserted 
straight in.

27.

Do not allow the flat-blade screwdriver to fall when you are holding 
it in a release hole.

28.

Do not bend a wire past its natural bending radius or pull in it with 
excessive force. Doing so may break the wires.

29.

Do not insert more than one wire into each terminal insertion hole.

30.

To prevent wire materials from smoking or igniting, use the wiring 
materials given in the following table.

Note:

Please use Ferrules with UL certification (R/C).

31.

Use only the specified wires for wiring.

32.

When wiring the terminals, allow some leeway in the wire length.

33.

Make sure that the power supply is turned OFF before you change 
any DIP switch setting.

Observe the following operating methods to 
prevent failure and malfunction.

1.

Use the power supply voltage, input power, and other power 
supplies and converters with suitable capacities and rated outputs.

2.

The distortion in the input waveform must be 30% max. If the input 
waveform is distorted beyond this level, it may cause unnecessary 
operation.

3.

Error will be large if the product is used for thyristor or inverter 
control.

4.

When cleaning the product, do not use thinners or solvents. Use 
commercial alcohol.

5.

If you use stranded wires, make sure that there are no loose wire 
strands.

6.

If you wire crossovers and connect terminal blocks in parallel, a 
large current will flow. Make sure that the current does not exceed 
10 A.

7.

The terminal block may be damaged if the recommended tool is 
not used. Use the recommended flat-blade screwdriver to operate 
the release holes.

Correct Mounting Direction, Mounting, and 
Removing

Mounting to DIN Track

To mount the Relay to a DIN Track, hook the Relay onto the DIN 
Track and press the Relay in the direction of the arrow until you hear 
it lock into place.

Removing from the DIN Track

To remove the Relay, insert a screwdriver into the hook on the top or 
bottom and pull out the hook to release the Relay.

• Leave at least 30 mm of space between the product and other 

devices to allow easy installation and removal.

Precautions for Safe Use

Recommended wire

Stripping length

With Ferrules

Without 

Ferrules

0.25 to 1.5mm

2

/Equivalent to AWG24 to 16

10 mm

8 mm

Precautions for Correct Use

(1)

(2)

PFP-100N (100 cm)
PFP-50N (50 cm)

Applicable DIN Tracks

30 mm min.

Содержание K8DT-AS Seriesl

Страница 1: ...K8DT AS2 Options Order Separately Front Cover Refer to Safety Precautions on page 10 Refer to page 9 for commonly asked questions For the most recent information on models that have been certified for...

Страница 2: ...DC Approx 5 Direct input Continuous input at 120 of maximum input 1 s at 150 100 mA AC DC I2 COM 10 to 100 mA AC DC Approx 1 Direct input 500 mA AC DC I3 COM 50 to 500 mA AC DC Approx 0 2 Direct input...

Страница 3: ...rules Applicable wire size 0 25 to 1 5 mm2 AWG24 to AWG16 Wire insertion force 8 N max for AWG20 wire Screwdriver insertion force 15 N max Wire stripping length 8 mm Ferrule length 8 mm Current capaci...

Страница 4: ...copper wires with a rating of 75 C or an equivalent rating Inside Inside 1 Current Input AS1 2 Output C Relay Output T Transistor Output 3 Power Supply Voltage A 100 to 240 VAC D 24 VAC DC No polarit...

Страница 5: ...ge Contacts 11 12 Set value Alarm indicator Lit Contacts 11 14 or transistor output Input Delay time 250 ms reference value Terminal block See note Terminal block See note Current knob SV Hysteresis k...

Страница 6: ...front of the Unit For the K8DT AS SW1 is not used Note Open the DIP switch cover to set the DIP switch Keep the DIP switch cover closed while the power supply to the Relay is ON Model Setting range I...

Страница 7: ...et Value SV of 50 and Overcurrent Operation Operation will be at 100 A and resetting at 90 A when the hysteresis HYS is set to 10 Operating Time The operating time is set using the operating time knob...

Страница 8: ...3 1 7 1 7 9 3 76 Two M5 screw holes or two 5 5 dia holes OMRON CT K8AC CT200L Mounting Hole Dimensions Note The OMRON Current Transformer CT is designed to be used with the K8DT AS3 Use terminals k an...

Страница 9: ...ely 30 A The startup current will exceed the overload capacity rating 150 for 1 s of the K8DT AS1 and K8DT AS2 and result in failure of the Relay To monitor the motor load use the K8DT AS3 Overload ca...

Страница 10: ...ails monitoring and alarm outputs may fail to operate This may result in physical damage to the facilities equipment or other devices that are connected to it To reduce this risk inspect the Relay reg...

Страница 11: ...pply power to the product 22 Do not install the product immediately next to heat sources 23 Perform periodic maintenance 24 Do not wire anything to the release holes 25 When you insert a flat blade sc...

Страница 12: ...rom the release hole Checking Connections After the insertion pull gently on the wire to make sure that it will not come off and the wire is securely fastened to the terminal block To prevent short ci...

Страница 13: ...re is basic insulation between the power supply terminals and input terminals There is basic insulation between the power supply terminals and output terminals There is basic insulation between the in...

Страница 14: ...MEMO 14...

Страница 15: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Страница 16: ...IL 60169 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron...

Отзывы: