In the interest of product improvement, specifications are subject to change without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. L013-E1-05

OMRON Corporation

Industrial Automation Company

Control Devices Division H.Q.
Analog Controller Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7080/Fax: (81)75-344-7189

Printed in Japan
0506-0.3C (0696) (M)

!

WARNING

Do not short the terminals of, disassemble, deform under 
pressure, or incinerate the Battery. Doing so may result in 
minor injury due to bursting, ignition, or leakage of fluid. 

!

CAUTION

Do not touch any of the terminals or the back panel while 
power is being supplied. Doing so may result in electric 
shock. Be sure to mount the terminal cover after wiring.

Before changing times or other settings while power is 
being supplied, either turn OFF the power on the load 
side or set the output ON/OFF switch to OFF and confirm 
the safety of the system. Unexpected operation may 
occasionally result. 

Tighten the terminal screws to the specified torque. 
Loose screws may occasionally result in fire or 
malfunction.

Do not allow metal fragments or lead wire scraps to fall 
inside the Product. This may occasionally cause electric 
shock, fire, or malfunction. 

Never disassemble, repair, or modify the Product. This 
may occasionally cause electric shock, fire, or 
malfunction.

Do not use the Product where flammable or explosive gas 
is present. There may occasionally be a risk of explosion 
resulting in minor injury. 

Содержание H2F -

Страница 1: ...ntrol outputs Minute dial assures accurate settings Models with memory protection available Control outputs can be manually turned ON OFF Designed for surface flush or track mounting Model Number Structure Model Number Legend 1 Operation cycle D 24 hour W 1 week 2 Motor type None Synchronous motor M Quartz motor 3 Mounting method None Flush mounting F Surface mounting DIN track mounting 4 Output t...

Страница 2: ...tz motor with memory protection Flush SPST NO H2F D H2F DM H2F WM SPDT H2F DC H2F DMC H2F WMC Surface track SPST NO H2F DF H2F DMF H2F WMF SPDT H2F DFC H2F DMFC H2F WMFC Extra Programming Tabs 1 pair for each ON OFF See note 1 Y92S 21 Rechargeable Battery See note 2 Y92S 42 Operation period Minimum division Minimum set time Maximum set time 24 hour 15 min 15 min 23 h 45 min 1 week 1 h 2 h 166 h Op...

Страница 3: ...ax Memory protection against power failure 180 h min See note 3 Insulation resistance 100 MΩ min at 500 VDC Dielectric strength 2 000 VAC 50 60 Hz for 1 min between current carrying terminals and non current carrying metal parts 1 000 VAC 50 60 Hz for 1 min between non continuous contacts Vibration resistance Destruction 16 7 Hz 2 mm single amplitude Malfunction 10 to 55 Hz 0 25 mm single amplitud...

Страница 4: ...to the load 2 Do not exceed the following torque when tightening the screws Specified torque 0 8 N m Maximum torque 0 98 N m 3 When connecting leads to the terminal block use the same wire size for all leads If different wire sizes are used the thinner leads may come off during operation 4 Recommended lead wires AWG18 to AWG24 cross section 0 205 to 0 823 mm2 solid or twisted wire 5 When using cri...

Страница 5: ...ated Mounting Dimensions Surface Mounting H2F DF DMF WMF Track Mounting H2F DFC DMFC WMFC Mounting Holes M3 5 6 29 Two M3 holes Screw size M3 x 45 included Flush Mounting H2F D DM WM DC DMC WMC Panel Cutout Recommended panel thickness 1 to 3 2 mm Note The mounting adapter and screws are included 65 5 ...

Страница 6: ...Time Setting To set the time turn the center knob clockwise to the correct time Turning it counterclockwise or turning it with your fingers hooked on the setting bracket may cause a malfunction With 24 hour models set the hour to the arrow on the upper left cor ner of the front panel and the minute to the arrow on the center knob With 1 week models set the day of the week to the arrow on the upper...

Страница 7: ...F Be sure to load the Battery before using the H2F If the Battery is not loaded the H2F will not work properly Be sure to load the Battery with the correct polarity The polarity is indicated in the battery box After loading the Battery be sure to place the cover on the battery box The Battery is fully charged before shipment The Battery may lose its charge while the Battery is stored Therefore the...

Страница 8: ...of the terminals or the back panel while power is being supplied Doing so may result in electric shock Be sure to mount the terminal cover after wiring Before changing times or other settings while power is being supplied either turn OFF the power on the load side or set the output ON OFF switch to OFF and confirm the safety of the system Unexpected operation may occasionally result Tighten the te...