6-1 Setting the internal DIP-Switches
15
Section 6:
Operating procedures
6-1
Setting the internal DIP-Switches
•
Disconnect the SLC's power supply and remove the connector side of the transceiver, so that you can
access the two banks four-way dip-switches located there.
•
Use a suitably sized screwdriver to set the dip-switches as per the required configuration according to
the following tables.
6-1-1
Selection of reset mode
!
ATTENTION
In every transceiver unit there are two separate dip-switch banks. The two banks must be set in the
same way to get a valid configuration.
Dip switches number 1 and 2, act on the partial muting configuration.
See "Partial muting configuration" chapter 7.3.
Single switch number 4
Reset
OFF
Manual
ON
Automatic (Default setting)
Single switch number 3
No function
OFF
DEFAULT SETTING
ON
NOT ALLOWED