- 61 - 

ANNEX4 FUNCTION SETTING CARD 

F3SN 

FUNCTION SETTING 

VALUE 

Function Valid/Invalid 

Fixed blanking 
 

Blanked beam 

________________ (List selected beams) 

Function Valid/Invalid 
Floating Beam 

1/2/3/Clear 

Sequential beam 

Valid/Invalid 

Floating blanking 
 

Outermost beam invalid  Valid/Invalid 

Auxiliary output 
 

Setting value 

L-on/D-on/Light diagnosis/ Lockout/   
Outermost beam/ Specified beam/Blanking 

Ext. indicator output  Setting value 

L-on/D-on/Light diagnosis/ Lockout 

Function Valid/Invalid 

External device   
monitoring 

Acceptable delay time 

___________ms (100 to 600ms) 

Start interlock 

Function 

Valid/Invalid 

Restart interlock 

Function 

Valid/Invalid 

ID setting 

Setting value 

___________ (0000 to 9999) 

F3SH 

FUNCTION SETTING 

VALUE 

Auxiliary output 
 

Setting value 

L-on/D-on/Light diagnosis/ Lockout/   
Outermost beam/ Specified beam 

Ext. indicator output  Setting value 

L-on/D-on/Light diagnosis/ Lockout 

Function Valid/Invalid 

External device   
monitoring 

Acceptable delay time 

___________ms (100 to 600ms) 

Start interlock 

Function 

Valid/Invalid 

Restart interlock 

Function 

Valid/Invalid 

ID setting 

Setting value 

___________ (0000 to 9999) 

F3ZN 

FUNCTION SETTING 

VALUE 

Function Valid/Invalid 

Fixed blanking 
 

Blanked beam 

________________ (List selected beams) 

Function Valid/Invalid 
Floating Beam 

1/2/3/Clear 

Sequential beam 

Valid/Invalid 

Floating blanking 
 

Outermost beam invalid  Valid/Invalid 

Output2 
 

Setting value 

L-on/D-on/Light diagnosis/ Lockout/   
Outermost beam/ Specified beam/Blanking 

Ext. indicator output  Setting value 

L-on/D-on/Light diagnosis/ Lockout 

Threshold Adj. 

Setting value 

___________ (18 to 100) 

ID setting 

Setting value 

___________ (0000 to 9999) 

 
 

 

 
 
 

 

OMRON CORPORATION 

Industrial Automation Company 
Industrial Sensors Division 
Sensing Devices and Components Division H.Q. 
Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan 
Tel:0120-919-066 (Free call) 
 

OMRON ELECTRONICS LLC 

After Sales Support Engineering Services Department 
One Commerce Drive, Schaumburg, IL 60173-5302 U.S.A. 
Phone: 1-847-843-7900 / Fax: 1-847-843-7787 
 

OMRON CANADA INC. 

Technical Sales and Services –Toronto 
885 Milner Avenue, Scarborough, Ontario M1B 5V8 
CANADA 
Phone: 1-416-286-6465 / Fax: 1-416-286-6648   
Technical Sales and Services -Montreal (French Language) 
Phone: 1-514-636-6676 / Fax: 1-514-636-2959 
 

EUROPEAN H.Q.

 

OMRON EUROPE B.V. 
Wegalaan 67-69 P.O.BOX 13 2130AA Hoofddorp The 
Netherlands 
Phone: 31-23-56-81-300 / Fax: 31-23-56-81-388 
 

AUSTRIA 

OMRON Electronics G.m.b.H 
Brunner Strasse 81,Box 323 A-1230 vienna 
Phone: 43-1-801-90-0 / Fax: 43-1-804-48-46   

 

BELGIUM 

OMRON ELECTRONICS NV/SA 
Stationsstraat 24 B-1702 Groot-Bijgaarden Belgium 
Phone: 32-2-4662-480 / Fax: 32-2-4660-687   
 

CZECH 

OMRON ELECTRONICS 
spol.s.r.o.Srobarova 6 PRAHA 10 101 00    Czech Republic 
Phone: 420-2-67-31-12-54, 420-2-71-73-13-19 
Fax: 420-2-71-73-56-13 
 

DENMARK 

OMRON ELECTRONICS A/S 
Odinsvej 15 DK-2600 GLOSTRUP Denmark   
Phone: 45-43-44-00-11 / Fax: 45-43-44-02-11 
 

FINLAND

 

OMRON ELECTRONICS OY 
Mets-npojankuja 5 FIN-02130 ESPOO, Finland 
Phone: 358-9-5495-800 
Fax: 358-9-5495-8150, 358-9-5495-8155(CS) 

 
FRANCE 

OMRON ELECTRONICS S.a.r.l. 
19,rue du Bois Galon 94121 FONTENAY SOUS BOIS 
France 
Phone: 33-1-49-74-70-00 / Fax: 33-1-48-76-09-30 
 

GERMANY 

OMRON ELECTRONICS G.m.b.H.

 

Elisabeth-Selbert-Strasse 17,40764 
Langenfeld Germany 
Phone: 49-2173-6800-0 / Fax: 49-2173-6800-400 
 

HUNGARY 

OMRON ELECTRONICS Kft. 
H-1046 Budapest Kiss Erno u. 1-3. Hungary 
Phone: 36-1-399-3050 / Fax: 36-1-399-3060 

ITALY 

OMRON ELECTRONICS S.r.l. 
Viale Certosa, 49 20149 Milano- Italy 
Phone: 39-02-32681 / Fax: 39-02-325154 
 

NETHERLANDS 

OMRON ELECTRONICS B.V.     
Wegalaan 61 2132 JD Hoofddorp. Postbus 582 2130 AN 
Hoofddorp Netherlands   
Phone: 31-23-5681100 / Fax: 31-23-5681188 
 

中国 
欧姆龍(中国)有限公司 
中国北京西長安街 88 号  北京首都時代広場 1028 室    100031

 

Phone: 86-10 8391-3005 / Fax: 86-10-8391-3688 
 

香港歐姆龍亞洲有限公司 
香港九龍尖沙咀廣東道 25 号  港威大廈第2座 601-9 室

 

Phone: 852-2375-3827 / Fax: 852-2375-1475 
 

台灣 
台灣歐姆龍股  有限公司  總公司 
台灣台北市復興北路 363 号  弘雅大楼6楼

 

Phone: 886-2-2715-3331 / Fax: 886-2-2712-6712 
 

大韓民国 
韓国OMRON株式会社 
大韓民国 Seoul 市江南区新沙洞 618-3 New Seoul Bldg. 3 階

 

Phone: 82-2-512-0871, 82-2-549-2766 (English/Japanese) 
Fax: 82-2-517-9033 
 

SINGAPORE 

OMRON ASIA-PACIFIC PTE LTD 
83 Clemenceau Avenue, #11-01 UE Square, Singarore 
239920 Singapore 
Phone: 65-6-835-3011 / Fax:    65-6-835-2711 
 

AUSTRALIA 

OMRON ELECTRONICS PTY. LTD. 
71 Epping Road, North Ryde, Sydney NSW 2113 Australia 
Phone: 61-02-9878-6377 / Fax: 61-02-9878-6981 
 

INDONESIA 

OMRON ASIA PACIFIC PTE. LTD. 
INDONESIA REPRESENTATIVE OFFICE GRAHA 
PRATAMA FLOOR3A, JL MT HARYONO KAV. 15, JAKARTA 
12810 Indonesia 
Phone: 62-21-8370-9555 / Fax: 62-21-8370-9550 
 

MALAYSIA

 

OMRON ELECTRONICS SDN. BHD. 
2.01, Level 2, Wisma Academy, 4A, Jalan 19/1, 46300 
Petaling Jaya, Selangor Darul Ehsan, Malaysia   
Phone: 603-79547323, 603-76250801 / Fax: 603-79546618 
 

NEW ZEALAND 

OMRON ELECTRONICS LIMITED. 
65 Boston Road,Mt Eden Auckland New Zealand 
Phone: 64-9-358-4400 / Fax: 64-9-358-4411 
 

THAILAND 

OMRON ELECTRONICS CO., LTD. 
RASA TOWER 20TH FLOOR, #555 PHAHOLYOTHIN RD., 
CHATUCHAK, BANGKOK 10900 Thailand 
Phone: 66-2-937-0500, CRM call center 66-2-942-6700 
Fax: 66-2-937-0501

 

 

Содержание F39-MC11

Страница 1: ...m date of sale by OMRON OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED REGARDING NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ANY BUYER OR USER ACKN...

Страница 2: ...EN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM PROGRAMMABLE PRODUCTS OMRON shall not be respo...

Страница 3: ...volves a change of the safety distance Always recalculate and re measure the safety distance to confirm that it meets the applicable standards after the change Failure to do so may cause the machine t...

Страница 4: ...nal indicator output 27 8 6 External device monitoring 30 8 7 Start interlock 31 8 8 Restart interlock 32 8 9 Threshold adjustment 33 8 10 Setting initialization 34 8 11 ID setting 35 8 12 Threshold t...

Страница 5: ...load Bank lock Protect Setting lock Change password Setting limitation Accessible For the sensor having the specific serial number this function is unavailable Refer to 1 2 Available function and Sens...

Страница 6: ...02 or aaaabcc aaaa can be any numeric characters b can be any alphanumeric characters cc is greater than 03 The functional group B The following serial numbers correspond to the functional group B Ser...

Страница 7: ...ector when F39 MC is not in use Brief description of Operation keys 6 CANCEL ENTER DOWN R L UP MONITOR SET COPY PROTECT FUNCTION 3 1 Communication connection indicator CONNECT This indicator will ligh...

Страница 8: ...connector Emitter Receiver Emitter Receiver 8 4 2 Diagram for Wiring of Branching Connector Front View Pin No Signal 1 24 V 24VDC 2 RS 485 A 3 0V 4 RS 485 B CAUTION The F39 MC receives its power from...

Страница 9: ...with the power supply of the sensor When the F39 MC power is ON it confirms its connection to sensor When connection is succeeded it displays as follows Communication connecting indicator is lit Displ...

Страница 10: ...e item of respective function Monitor Set Section8 page14 Copy Section9 page41 Protect Section10 page45 DOWN UP MONITOR SET COPY PROTECT FUNCTION MONITOR SET COPY PROTECT FUNCTION MONITOR SET COPY PRO...

Страница 11: ...the setting can only be done under observance of laws standards which are related to safe operation of the product This function enables the monitoring of current set values and functions of the senso...

Страница 12: ...a power supply should be dropped a sensor may not carry out normal operation 16 8 1 Fixed blanking F3SN F3ZN CAUTION In order prevent access to a dangerous area fixed barrier guards must be placed in...

Страница 13: ...clear Note Models produced before April 2002 can not use setting of Surveillance mode Sensors which has specific serial number also can not use the setting If the surveillance mode is set to above mo...

Страница 14: ...n valid Place an object where you want to be blanked Select 2 tch Ent Beams select Send setting to sensor Setting completed good displayed ONE POINT After setting has completed you can confirm the bla...

Страница 15: ...OFF when 2 or more beams are blocked 22 CAUTION Use of floating blanking function involves a change of the safety distance Always recalculate and re measure the safety distance to confirm that it meet...

Страница 16: ...alid OFF Invalid ON Valid OFF Invalid GOOD ERR 24 8 3 Auxiliary output F3SN F3SH This is a non safety related output used to display a status This output cannot be used for the purpose of safety This...

Страница 17: ...cked beams Err is displayed 3 AUX 1 D ON 2 L ON 3 L DG 4 L OU 5 O B M 6 BLN 7 SPC GOOD ERR SEND GOOD ERR 26 Setting completed Error Send to sensor Specified beam Blanking monitor Outermost beam monito...

Страница 18: ...inks in a cycle of 1 seconds bln 3 It blinks in a cycle of 2 seconds Note 1 F3ZN can set up only 1 4 2 There are some which cannot set up above 5 7 by the serial number about F3SN and F3SH 3 There are...

Страница 19: ...lfunction of external device which controls hazardous area of machine e g contact welding The determination time can be set in respect to the response time of relay being used The setting time must be...

Страница 20: ...nter Key Up Down Key Go to after 1 sec 6 SIL 1 FUN SEND GOOD ERR Go to ON Valid OFF Invalid 32 8 8 Restart interlock F3SN F3SH When this function is ON the outputs remain in their OFF state i e interl...

Страница 21: ...nsor Blinking Cancel Key Enter Key Up Down Key Go to after 1 sec 8 TH 18 SEND GOOD ERR 34 8 10 Setting initialization F3SN F3SH F3ZN This function returns the sensor setting to their default value Def...

Страница 22: ...level value 2 Calculate the optimal value of ON threshold level and adjust manually 3 Write ON threshold level into sensor CAUTION Perform this function at the condition that all the beams of a senso...

Страница 23: ...played as show in the figure below The bottom position means the side with power supply lines Max Min Level Lower position Top Lower position Middle Lower position Bottom 38 2 Calculate the optimal va...

Страница 24: ...to 1 display for receiving light level value No 1 40 8 13 Error log view F3SN F3SH F3ZN The error log recorded in sensor is displayed The error log is written with error codes See the contents of err...

Страница 25: ...ible For example copying from F3SN to F3ZN is not possible 2 Copying to sensor with different detection capability or beam gap is not possible Switch modes are illustrated below Section9 1 42page Sect...

Страница 26: ...displayed as Good When a power supply should be dropped a sensor may not carry out normal operation Download Download Setting completed Error Select bank number using UP DOWN keys Note F3SN F3SH has o...

Страница 27: ...illustrated below Section10 1 46page Section10 2 47page Section10 3 48page UP DOWN Key Blinking 1 Setting lock 3 Setting limitation 2 Change password 1 S LC 2 PAS 3 LMT 46 10 1 Setting lock Prohibit s...

Страница 28: ...n qualified person Note Please remember changed password If you forget please contact OMRON 48 10 3 Setting limitation Limit the re settable functions in order to prevent hazardous setting by mistake...

Страница 29: ...Go to after 1 sec RST Reset limitation RST Reset limitation Blinking Cancel Key Enter Key Up Down Key 50 11 DISCONNECT F39 MC After the setting has completed be sure to disconnect cable and F39 MC be...

Страница 30: ...1 Mount correctly see section 4 2 Use power supply with enough capacity 2 Communication connection indicator of F39 MC will not lit or not conn is displayed Cause 1 F39 MC has powered on after sensor...

Страница 31: ...rface displacement of beams or deterioration of LED Unstable condition indicates that the light level remains within 20 of threshold value 54 Terms Explanation Light ON Auxiliary output output2 Ext in...

Страница 32: ...Manual Valid Invalid Set each beam 1 to 3 Surveillance mode Note1 Lockout mode at the light receiving condition Setting release at the light receiving condition ALL Fixed blanking Send to sensor ALL F...

Страница 33: ...ator output Send to sensor Function Valid Invalid Setting time 100 to 600ms every 5ms External device monitoring Send to sensor Function Valid Invalid Start interlock Send to sensor Function Valid Inv...

Страница 34: ...60 ANNEX3 ERROR CODE LIST Error code Contents and remedy A8 AA Wiring error Wiring is not performed correctly Please confirm a sensor instruction manual and check wiring A3 Error of the EDM function...

Страница 35: ...X 13 2130AA Hoofddorp The Netherlands Phone 31 23 56 81 300 Fax 31 23 56 81 388 AUSTRIA OMRON Electronics G m b H Brunner Strasse 81 Box 323 A 1230 vienna Phone 43 1 801 90 0 Fax 43 1 804 48 46 BELGIU...

Отзывы: