- 47 -
10.2 Change
password
Change password (4 digit number) to release setting lock.
The default value is “0000”.
Change password
Enter old password
Password change
Enter new password
Blinking
[Cancel] Key
[Enter] Key
Enter 4 digit number (0000 to 9999)
"ERR" is displayed if password unmatched
Enter 4 digit number (0000 to 9999)
①
2.PAS
②
OLD
③
NEW
④
GOOD
Go to ①
after 1 sec
<Usage>
We strongly recommend to use with password other than “0000”, and
with Setting lock function. This will prevent unauthorized setting
change by un-qualified person.
<Note >
Please remember changed password.
If you forget, please contact OMRON.
- 48 -
10.3 Setting
limitation
Limit the re-settable functions in order to prevent hazardous setting by
mistake.
The following can be set;
・
Maximum fixed blanking zones (0 to 3 zones)
・
Maximum fixed blanking beams (1 to 9 beams)
・
Maximum floating blanking beams (0 to 3 beams)
The value which exceeds above set value, cannot be set to the sensor.
<How to use>
Set limitation beforehand.
This prevents hazardous settings caused by mistake.
<Description>
“Fixed blanking zone” means is number of set of beam(s) that can be
blanked.
<Note >
This function does not protect against “COPY” function. (Only
protected against MONITOR/SET function).