- 29 -
<F3SN, F3SH, F3ZN>
About F3SN and F3SH, it becomes the following displays by the serial
number.
③-1
①
Setting completed
Error
Send to sensor
②-4
Lockout
②-3
Light diagnosis
②-2
Light ON
②-1
Dark ON
Blinking
[Cancel] Key
[Enter] Key
[Up][Down] Key
Go to
①
after 1 sec.
1.D.ON
2.L.ON
3.L.DG
4.L.OU
SEND
③-2
GOOD
ERR
Ext. indicator output
4.E.I.O.
- 30 -
8.6
External device monitoring
<F3SN, F3SH>
This function can detect malfunction of external device which controls
hazardous area of machine. (e.g. contact welding)
The determination time can be set in respect to the response time of
relay being used. The setting time must be between 100ms to 600ms
and can be set in 5ms increments.
①
②-1
Go to
②-2
Change delay time
using [UP][DOWN]
[L][R]keys.
(100 to 600 ms;
every 5ms)
②-2
Go to
②-3
②-3
Ext. device monitor
Function valid
Acceptable delay time
Send to sensor
Function valid
Error
Setting completed
Select time (ms)
Blinking
[Cancel] Key
[Enter] Key
[Up][Down] Key
Go to
①
after 1 sec.
5.EDM
②-1-1
②-2-1
②-3-1
1.FUN
2.TIM
SEND
ON:Valid
OFF:Invalid
300
GOOD
ERR