Appendix A
Specifications
63
Item
Specification
Shock resistance
Malfunction:
Max. acceleration:
150 m/s
2
Direction:
3-axis, 6 directions
Times:
18 times in total
Destruction:
Max. acceleration:
200 m/s
2
Direction:
3-axis, 6 directions
Times:
18 times in total
Enclosure rating
IP00
Dimensions
E5ZE-8
-E (without casing):
169.5 x 192 x 58 mm
E5ZE-8
B-E (with casing):
173.5 x 230 x 65 mm
E5ZE-8
D1
B (DeviceNet):
173.5 x 253 x 65 mm
Set value backup
Lithium battery
Set value backup period
10 years min. provided that the ambient temperature is within the normal room tempera-
ture
Weight
Without casing: Approx. 900 g
With casing:
Approx. 1,700 g (including 2 mounting brackets)
Note 1. These alarm mode settings include the standby sequence.
2. When DeviceNet is used to set the alarm settings, the upper limit is 3,000.0
°
C/
°
F
(in units of 0.1)
3. The applicable standards for the temperature sensor input types are as follows:
K, J, T, E, R, S, B: JIS C1602-1981
L:
Fe-CuNi, DIN 43710-1985
U:
Cu-CuNi, DIN 43710-1985
N:
Nicrosil-NisiL, IEC584-1, 1977; Amendment No. 1, 1989
W:
W5Re/W26Re, ASTM E988-1990
PL II:
According to PLATINEL II Electromotive Force Table by ENGELHARD
JPt100:
JIS C 1604-1989, JIS C1606-1989
Pt100:
JIS C 1604-1989, JIS C1606-1989 IEC 751