2-4
Section
Installation
16
2-4-2 Mounting
Mount the Unit using the methods shown here. The Unit will not operate properly
if other methods are used to mount the Unit.
Precautions
•
Use the following mounting screws. Make sure the length of the screws is ap-
propriate for the mounting panel used.
E5ZE-8
B:
4 x M4 screws
•
Use spring and flat washers and tighten to a torque of 0.43 to 0.58 N
m {4.4 to
5.9 kgf
cm}.
•
Do not mount the terminal block with the connectors facing upwards. Doing so
may cause measurement errors.
Secure the mounting bracket using the screws provided according to the ap-
propriate mounting method. Tighten to a torque of 0.43 to 0.58 N
m {4.4 to
5.9 kgf
cm}.
Mounting Models
Secure the mounting
bracket
Mounting screws
(4 x M4 + spring
and flat washers)
Secure the mounting
bracket
Mounting screws
(4 x M4 + spring
and flat washers)
Panel
Panel
Mounting Bracket