E5AK-T/E5EK-T
E5AK-T/E5EK-T
4
Description
Model
Specification
Output Unit
E53-R
Relay
E53-S
SSR
E53-Q
Pulse (NPN) 12 VDC at 40 mA max.
E53-Q3
Pulse (NPN) 24 VDC at 20 mA max.
E53-Q4
Pulse (PNP) 24 VDC at 20 mA max.
E53-C3
Linear (4 to 20 mA) under a load of 600
Ω
max.
E53-C3D
Linear (0 to 20 mA) under a load of 600
Ω
max.
E53-V34
Linear (0 to 10 V) under a load of 1 k
Ω
min.
E53-V35
Linear (0 to 5 V) under a load of 1 k
Ω
min.
Note:
The Digital Controller uses a dedicated, high-resolution Output Unit. The E53-C Current Output Unit for the E5
j
X cannot be used with
the Digital Controller.
Description
Model
Specification
Option Unit
E53-AKB
Event input
E53-AK01
Communication (RS-232C)
E53-AK02
Communication (RS-422)
E53-AK03
Communication (RS-485)
E53-AKF
Transfer output
Note:
1. The Option Unit can be used either by the E5AK or E5EK.
The E5EK allows only one Option Unit to be mounted.
Inspection Report
The Digital Controller can be provided together with an inspection report.
Refer to the following legend with the suffix “K” when ordering a model provided together with an inspection report.
E5
j
K-TAA2-K, E5
j
K-TPRR2-K
Accessories (Order Separately)
Name
Model
Hole diameter
Current Transformer
E54-CT1
5.8 dia.
E54-CT3
12.0 dia.
Note:
No CT is required unless the heater burnout alarm function is used.
Name
Model
Connectable models
Terminal Cover
E53-COV0809
E5AK
E53-COV08
E5EK
Unit Label
Model
Y92S-L1
Ranges
Platinum Resistance Thermometer
Input (switch selectable)
JPt100
Pt100
Range
°
C
–199.9 to 650.0
–199.9 to 650.0
°
F
–199.9 to 999.9
–199.9 to 999.9
Setting
0
1
Thermocouple
Input (switch
selectable)
(see note)
K1
K2
J1
J2
T
E
L1
L2
U
N
R
S
B
W
PL
II
Range
°
C
–200
to
1,300
0.0 to
500.0
–100
to
850
0.0 to
400.0
–199.9
to
400.0
0 to
600
–100
to
850
0.0 to
400.0
–199.9
to
400.0
–200
to
1,300
0 to
1,700
0 to
1,700
100
to
1,800
0 to
2,300
0 to
1,300
°
F
–300
to
2,300
0.0 to
900.0
–100
to
1,500
0.0 to
750.0
–199.9
to
700.0
0 to
1,100
–100
to
1,500
0.0 to
750.0
–199.9
to
700.0
–300
to
2,300
0 to
3,000
0 to
3,000
300
to
3,200
0 to
4,100
0 to
2,300
Setting
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Note:
Setting number is factory-set to 2 (K1).