* Value one hour after the product is turned on. Note, however, that external disturbance sometimes causes minute output.

8. Ratings

Ratings and Specifications

Type

Twin output model

Analog output model

Model

E4C-UDA11

E4C-UDA41

E4C-UDA11AN

E4C-UDA41AN

NPNoutput

PNPoutput

NPNoutput

PNPoutput

Connection method

Prewired

Supply voltage

12 to 24 VDC ± 10%, ripple 10% max.

Current consumption

80 mA max.

Control output

NPN open collector (26.4 VDC max.)

Load current: 50 mA max., Residual voltage: 1 V max.

Hysteresis

2.0% F.S.max.

Timer

OFF/OFF-delay/ON-delay/one-shot

Timer time

1 ms to 5 s

Analog
output

Output form

 - 

Voltage output (DC 1 to 5 V)

Connected load

 - 

10 k

 min.

Temperature
characteristics

 - 

0.3% F.S./

°

C

Resolution

 - 

2.0% F.S.max. *

Linearity

 - 

2.0% F.S.max.

Operating temperature

Operating: -25 to +55°C  Storage: -30 to +70°C (with no icing)

Operating humidity

Operating and storage: 35% to 85% (with no condensation)

Insulation resistance

50 M

 min. (by 500 VDC)

Dialectic strength

1,000 VAC, 50/60 Hz for 1 min

Vibration resistance

10 to 150 Hz, 0.75 mm double amplitude, 80 min each in X, Y, and Z directions

Shock resistance

500 mm/s

2

, 3 times each in X, Y and Z directions

Materials

Case: PBT (polybutylene terephthalate), Cover: Polycarbonate

Weight

Approx. 150 g

Accessories

Instruction Manual

I/O Circuit Diagrams

J

E4C-UDA11 (NPN type)

J

E4C-UDA41 (PNP type)

J

E4C-UDA11AN (NPN type)

J

E4C-UDA41AN (PNP type)

DC
12 to 24 V

Brown

Black  1CH output

Orange  2CH output

Blue

Internal circuit

Load

Load

DC
12 to 24 V

Brown

Black 1CH output

Orange 2CH output

Blue

Internal circuit

Load

Load

Brown

Blue

10 KW min.

DC
12 to 24 V

Black  Control output

Orange  Analog output

Internal circuit

Load

Load

Brown

Blue

10k

ǡ

MIN

DC
12 to 24 V

Black  control output

Orange

Analog

output

Internal circuit

Load

Load

1636705-7A_e4c-uda_E.fm  17 ページ  2005年11月15日 火曜日 午後4時58分

Содержание E4C-UDA

Страница 1: ...period if specified from date of sale by OMRON OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED REGARDING NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS...

Страница 2: ...ents where it can be exposed to inflammable explosive gas 2 Do not use this product in locations where it will be sprayed by water oil or chemical fumes or in steamy locations 3 Do not attempt to dism...

Страница 3: ...ic measurement values to the desired values twin output model only P 11 Judgment output setting This function selects the output method P 12 Analog output range setting This function sets the range an...

Страница 4: ...e DIN Track attachment JRemoval procedure Push the Amplifier Unit in direction 1 and pull out the Sensor Head connector end in direction 2 4 Basic Knowledge for Operation Mode Details SET Select this...

Страница 5: ...er 1SHT One shot timer Switch to the SET mode 1 Number of samples to average 2 Timer Timer time Not A B Current distance Threshold value Current distance and threshold value 3 Display switch Teaching...

Страница 6: ...l 2OUT 10 Output method setting In the case of the twin output model AREA 2BIT output 2BIT This is output only when there is a workpiece between two threshold value distances Range of two preSET point...

Страница 7: ...election Details NON near ON default Output turns ON when the distance between the workpiece and the Sensor Head is shorter than the threshold value FON far ON Output turns ON when the distance betwee...

Страница 8: ...a workpiece absent state Example In the case of a 50 to 300 mm type set the threshold value about 25 mm in front 3 Setting Threshold Values Workpiece present No workpiece present Workpiece Operation...

Страница 9: ...outside the sensing range Check the position of the workpiece and then execute teaching again NEAR error The difference between the maximum taught distance and the minimum taught distance is too small...

Страница 10: ...ent RUN SET Sub display Main display Select 6 BR by the MODE key Select the desired bank No 0 to 3 by the UP or DOWN key In this example bank 2 is selected Switch the SET RUN switch to RUN Select YES...

Страница 11: ...ODE key and then press the UP or DOWN key once Displays the current scaling execution state Press the UP or DOWN key to select ON and press the MODE key to apply the setting Press the UP or DOWN key t...

Страница 12: ...tput The distance is divided into four areas by the threshold values of each of channels 1CH and 2CH and the three mid points between each of these threshold values Four states are judged according to...

Страница 13: ...d setting Set the analog output referenced to the background distance 5 V First point second point 1 V Second point 5 V First point First point second point 1 V First point 5 V Second point The displa...

Страница 14: ...the setting is completed Align with the rear and hold down the MODE key for more than 3 seconds 1 0 5 50 300 Output voltage V Measured value mm Measured value mm 1 0 5 100 200 Output voltage V The di...

Страница 15: ...DOWN key for more than 3 seconds with the MODE key pressed Press the MODE key and then immediately press the DOWN key Switch to the RUN mode Current distance Threshold value The zero reset is canceled...

Страница 16: ...th the MODE key pressed Press the MODE key and then immediately press the UP key Switch to the RUN mode LOC ON RUN SET The sub display flashes twice and key entry is enabled Hold down the UP key for m...

Страница 17: ...5 to 55 C Storage 30 to 70 C with no icing Operating humidity Operating and storage 35 to 85 with no condensation Insulation resistance 50 M min by 500 VDC Dialectic strength 1 000 VAC 50 60 Hz for 1...

Страница 18: ...d M Shanghai 200120 China Tel 86 21 5037 2222 Fax 86 21 5037 2200 Regional Headquarters OMRON E UROPE B V Sensor Business Unit Carl Benz Str 4 D 71154 Nufringen Germany Tel 49 7032 811 0 Fax 49 7032 8...

Отзывы: