- 14 -
J
Setting procedure
3) Direct setting
Directly set the distance with respect to output (1 V, 5 V).
J
Setting procedure
Note: When the values of the first and second points are the same, "NEAR" flashes twice on the error display, and the points
must be set again.
The display moves to the next setting.
This completes setting, and the display returns
to regular measurement.
Switch the SET/RUN switch
to RUN.
Press the MODE key.
RUN
SET
Sub-display:
Main display:
Select [10AR] by the MODE key,
and then press the UP or DOWN key to select [RFCT].
Press the MODE key to apply the setting. The current
distance is displayed on the sub-display.
"OK" is displayed on the sub-display to indicate that
the setting is completed.
Align with the rear, and hold down the MODE key for
more than 3 seconds.
1
0
5
50
300
Output voltage
(V)
Measured
value (mm)
Measured
value (mm)
1
0
5
100 200
Output voltage
(V)
The display moves to the next setting.
This completes setting, and the display
returns to regular measurement.
Switch the SET/RUN switch
to RUN.
Press the MODE key.
RUN
SET
Sub-display:
Main display:
Select [10AR] by the MODE key,
and then press the UP or DOWN key to select [MFCS].
The distance value currently assigned to 1 V is displayed.
Press the UP or DOWN key to set the distance to assign to 1 V,
and press the MODE key to apply the setting.
The distance value currently assigned to 5 V is displayed.
"OK" is displayed on the sub-display to indicate that the setting
is completed.
Press the UP or DOWN key to set the distance to assign to 5 V,
and press the MODE key to apply the setting.