- 3 -
.
(1) This indicator lights when the output turns ON.
In the case of the twin output model, this indicator lights when the output of 1CH turns ON.
(2) This display shows the distance to the workpiece and function name.
(3) In the case of the twin output model, this indicator lights when the output of 2CH turns ON.
(4) This sub-display shows additional information and function settings for sensing.
(5) This switch selects the operating mode.
(6) In the case of the twin output model, this switch selects the channel to be displayed and set.
In the case of the analog output model, this switch selects whether to turn output ON when the workpiece is in the near
distance or the workpiece is in the far distance.
(7) These keys switch the display and set functions.
1. Part Names and Functions
2. List of Functions
Function Name
Overview
Page for Description
of Operation
Operating mode setting
This function sets the operating mode.
P.7
Threshold setting
This function sets the threshold values.
P.8
Bank setting/call
This function saves and reads settings.
P.10
Scaling setting
This function changes the display values for specific measurement values to the
desired values. (twin output model only)
P.11
Judgment output setting
This function selects the output method.
P.12
Analog output range setting
This function sets the range and display ratio of the analog output with respect to the
display value.
(analog output model only)
P.13
Zero reset/offset
This function sets the current distance to 0 (zero) or to any value.
P.15, P.15
Display inversion
This function inverts how the display for the distance to the workpiece is
incremented/decremented.
P.15
Keylock
This function disables key operation.
P.16
Initialization
This function returns the amplifier settings to their factory settings.
P.16
3. Installation & Connection
Connecting the Sensor Head
1. Open the protective cover.
2. Orient the Amplifier Unit so that the lock lever of the Sensor
Head connector is facing up, and push the Sensor Head into the
connector insertion slot as far as it can go.
To remove the Sensor Head, press down on the lock lever and draw
the Sensor Head out.
UP
SET
RUN 1
2
DOWN
MODE
(1) Operation indicator
(1CH)
(4) Sub-display (green display)
(7) Control keys
(5) SET/RUN switch
N
F
(2) Main display (red display)
(3) Twin output model: Operation indicator (2CH side)
Analog output model: None
(6) Twin output type: Channel switch
Analog output type: Operating mode switch
1
2
Lock lever
1636705-7A_e4c-uda_E.fm 3 ページ 2005年11月15日 火曜日 午後4時58分