- 3 -

.

(1) This indicator lights when the output turns ON.

In the case of the twin output model, this indicator lights when the output of 1CH turns ON.

(2) This display shows the distance to the workpiece and function name.
(3) In the case of the twin output model, this indicator lights when the output of 2CH turns ON.
(4) This sub-display shows additional information and function settings for sensing.
(5) This switch selects the operating mode.
(6) In the case of the twin output model, this switch selects the channel to be displayed and set.

In the case of the analog output model, this switch selects whether to turn output ON when the workpiece is in the near
distance or the workpiece is in the far distance.

(7) These keys switch the display and set functions.

1. Part Names and Functions

2. List of Functions

Function Name

Overview

Page for Description 

of Operation

Operating mode setting

This function sets the operating mode.

P.7

Threshold setting

This function sets the threshold values.

P.8

Bank setting/call

This function saves and reads settings.

P.10

Scaling setting

This function changes the display values for specific measurement values to the
desired values. (twin output model only)

P.11

Judgment output setting

This function selects the output method.

P.12

Analog output range setting

This function sets the range and display ratio of the analog output with respect to the
display value.
(analog output model only)

P.13

Zero reset/offset

This function sets the current distance to 0 (zero) or to any value.

P.15, P.15

Display inversion

This function inverts how the display for the distance to the workpiece is
incremented/decremented.

P.15

Keylock

This function disables key operation.

P.16

Initialization

This function returns the amplifier settings to their factory settings.

P.16

3. Installation & Connection

Connecting the Sensor Head

1. Open the protective cover. 
2. Orient the Amplifier Unit so that the lock lever of the Sensor

Head connector is facing up, and push the Sensor Head into the
connector insertion slot as far as it can go. 

To remove the Sensor Head, press down on the lock lever and draw
the Sensor Head out.

UP

SET

RUN 1

2

DOWN

MODE

(1) Operation indicator     

(1CH)

(4) Sub-display (green display)

(7) Control keys

(5) SET/RUN switch

N

F

(2) Main display (red display)

(3) Twin output model: Operation indicator (2CH side)
     Analog output model: None

(6) Twin output type: Channel switch
     Analog output type: Operating mode switch

1

2

Lock lever

1636705-7A_e4c-uda_E.fm  3 ページ  2005年11月15日 火曜日 午後4時58分

Содержание E4C-UDA

Страница 1: ...period if specified from date of sale by OMRON OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED REGARDING NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS...

Страница 2: ...ents where it can be exposed to inflammable explosive gas 2 Do not use this product in locations where it will be sprayed by water oil or chemical fumes or in steamy locations 3 Do not attempt to dism...

Страница 3: ...ic measurement values to the desired values twin output model only P 11 Judgment output setting This function selects the output method P 12 Analog output range setting This function sets the range an...

Страница 4: ...e DIN Track attachment JRemoval procedure Push the Amplifier Unit in direction 1 and pull out the Sensor Head connector end in direction 2 4 Basic Knowledge for Operation Mode Details SET Select this...

Страница 5: ...er 1SHT One shot timer Switch to the SET mode 1 Number of samples to average 2 Timer Timer time Not A B Current distance Threshold value Current distance and threshold value 3 Display switch Teaching...

Страница 6: ...l 2OUT 10 Output method setting In the case of the twin output model AREA 2BIT output 2BIT This is output only when there is a workpiece between two threshold value distances Range of two preSET point...

Страница 7: ...election Details NON near ON default Output turns ON when the distance between the workpiece and the Sensor Head is shorter than the threshold value FON far ON Output turns ON when the distance betwee...

Страница 8: ...a workpiece absent state Example In the case of a 50 to 300 mm type set the threshold value about 25 mm in front 3 Setting Threshold Values Workpiece present No workpiece present Workpiece Operation...

Страница 9: ...outside the sensing range Check the position of the workpiece and then execute teaching again NEAR error The difference between the maximum taught distance and the minimum taught distance is too small...

Страница 10: ...ent RUN SET Sub display Main display Select 6 BR by the MODE key Select the desired bank No 0 to 3 by the UP or DOWN key In this example bank 2 is selected Switch the SET RUN switch to RUN Select YES...

Страница 11: ...ODE key and then press the UP or DOWN key once Displays the current scaling execution state Press the UP or DOWN key to select ON and press the MODE key to apply the setting Press the UP or DOWN key t...

Страница 12: ...tput The distance is divided into four areas by the threshold values of each of channels 1CH and 2CH and the three mid points between each of these threshold values Four states are judged according to...

Страница 13: ...d setting Set the analog output referenced to the background distance 5 V First point second point 1 V Second point 5 V First point First point second point 1 V First point 5 V Second point The displa...

Страница 14: ...the setting is completed Align with the rear and hold down the MODE key for more than 3 seconds 1 0 5 50 300 Output voltage V Measured value mm Measured value mm 1 0 5 100 200 Output voltage V The di...

Страница 15: ...DOWN key for more than 3 seconds with the MODE key pressed Press the MODE key and then immediately press the DOWN key Switch to the RUN mode Current distance Threshold value The zero reset is canceled...

Страница 16: ...th the MODE key pressed Press the MODE key and then immediately press the UP key Switch to the RUN mode LOC ON RUN SET The sub display flashes twice and key entry is enabled Hold down the UP key for m...

Страница 17: ...5 to 55 C Storage 30 to 70 C with no icing Operating humidity Operating and storage 35 to 85 with no condensation Insulation resistance 50 M min by 500 VDC Dialectic strength 1 000 VAC 50 60 Hz for 1...

Страница 18: ...d M Shanghai 200120 China Tel 86 21 5037 2222 Fax 86 21 5037 2200 Regional Headquarters OMRON E UROPE B V Sensor Business Unit Carl Benz Str 4 D 71154 Nufringen Germany Tel 49 7032 811 0 Fax 49 7032 8...

Отзывы: