manualshive.com logo in svg
background image

E2EC

Ratings and Specifications

* The response frequency is an average value. 

Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 

DC 2-Wire Models

DC 3-Wire Models

Item

Model

E2EC-CR8D

@

E2EC-C1R5D

@

E2EC-C3D

@

E2EC-X4D

@

E2EC-CR5C1

E2EC-C2R5C1

Sensing distance

0.8 mm 

”

15%

1.5 mm 

”

10%

3 mm 

”

10%

4 mm 

”

10%

0.5 mm 

”

15%

2.5 mm 

”

10%

Set distance

0 to 0.56 mm

0 to 1.05 mm

0 to 2.1 mm

0 to 2.8 mm

0 to 0.3 mm

0 to 1.7 mm

Differential travel

10% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to 

Engineering Data

 on page 3.) 

Standard sensing 
object

Iron, 5 

—

 5 

—

 1 mm

Iron, 8 

—

 8 

—

 1 mm

Iron, 
12 

—

 12 

—

 1 mm

Iron, 5 

—

 5 

—

 1 mm Iron, 8 

—

 8 

—

 1 mm

Response frequency 

*

1.5 kHz

1 kHz

Power supply volt-
age (operating volt-
age range)

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

5 to 24 VDC (4.75 to 30 VDC), 
ripple (p-p): 10% max.

Current
consumption

---

10 mA max.

Leakage current

0.8 mA max.

---

Control 
output

Load 
current

5 to 100 mA

NPN open-collector output, 
100 mA max. (30 VDC max.)

Residual 
voltage

3 V max. (Load current: 100 mA, Cable length: 2 m)

1 V max. (Load current: 100 mA, 
Cable length: 2 m)

Indicators

D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)

Detection indicator (red)

Operation mode 
(with sensing object 
approaching)

D1 Models: NO
D2 Models: NC
Refer to the timing charts under 

I/O Circuit Diagrams

 on page 5 for details.

NO
Refer to the timing charts under 

I/O

Circuit Diagrams

 on page 5 for details.

Protection circuits

Load short-circuit protection, Surge suppressor

Surge suppressor

Ambient 
temperature range

Operating/Storage: 

25 to 70

“

C (with no icing or condensation)

Ambient 
humidity range

Operating/Storage: 35% to 95% (with no condensation)

Temperature 
influence

”

20% max. of sensing distance at 23

“

C in the temperature range of 

25 to 70

“

C

Voltage influence

”

2.5% max. of sensing distance at rated voltage in the rated voltage 

”

15%

range

”

5% max. of sensing distance at the 

rated voltage range in the voltage 
range of 4.75 to 30 V

Insulation 
resistance

50 M

:

 min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC for 1 min between current-carrying parts and case

500 VAC for 1 min between current-
carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 1,000 m/s

2

 10 times each in X, Y, and Z directions

Destruction: 500 m/s

2

 10 times each in 

X, Y, and Z directions

Degree of protection

IEC 60529 IP67, in-house standards: oil-resistant

IEC 60529 IP64

Connection method

Pre-wired Models (Standard cable length: 2 m)

Weight 
(packed state)

Approx. 45 g

Materials

Case

Brass

Sensing 
surface

ABS

Accessories

Amplifier Mounting Bracket, Instruction manual

Instruction manual

http://www.ia.omron.com/

2

(c)Copyright OMRON Corporation 2007   All Rights Reserved. 

Содержание E2EC -

Страница 1: ...e also available The model numbers are E2EC 5 example E2EC CR8D15 DC 3 Wire Models Models with different frequencies are also available The model numbers are E2EC 5 example E2EC CR5D15 Accessories Ord...

Страница 2: ...proaching D1 Models NO D2 Models NC Refer to the timing charts under I O Circuit Diagrams on page 5 for details NO Refer to the timing charts under I O Circuit Diagrams on page 5 for details Protectio...

Страница 3: ...nce X mm Distance Y mm Sensing Head Y X 4 3 2 1 0 3 1 2 0 1 2 3 4 4 Distance X mm Distance Y mm Sensing Head Y X 6 5 4 3 2 1 0 4 2 0 2 4 Distance Y mm Distance X mm Sensing Head Y X 0 6 0 5 0 4 0 3 0...

Страница 4: ...er Brass Distance X mm Side length of sensing object d mm Stainless steel SUS304 Iron X 5 4 3 2 1 0 5 35 30 25 15 20 10 d d t 1 mm Distance X mm Side length of sensing object d mm Brass Copper Stainle...

Страница 5: ...tor green Operation indicator red Control output 0 V V Load Brown Blue Prox imity Sensor main circuit Note The load can be connected to either the V or 0 V side 0 100 Sensing object Rated sensing dist...

Страница 6: ...Permissible Tightening Range and Torque x The tightening torque applied to the E2EC X4D Threaded Cylindrical Models must be 12 N m max Amplifier Mounting Bracket for DC 2 Wire Models Mounting 1 Insert...

Страница 7: ...8 25 5 35 5 18 8 dia 5 4 24 2 1 10 3 6 1 6 dia shielded robotics cable Standard length 400 mm 2 9 dia vinyl insulated round robotics cable with 2 conductors Conductor cross section 0 15 mm2 Insulator...

Страница 8: ...round cable with 3 conductors Conductor cross section 0 2 mm2 Insulator diameter 1 2 mm Standard length 2 m 2 The cable can be extended up to 50 m separate metal conduit 3 2 5 dia shielded cable Stan...

Страница 9: ...t The load short circuit protection function op erates when the power supply is connected with the correct polarity and the power is within the rated voltage range DC 3 Wire NPN Output Sensors DC 2 Wi...

Страница 10: ...stive load Non contact control system Inductive load Relay solenoid etc Steady state current inrush current Operating reset voltage current Lamp load Steady state current inrush current Open close fre...

Страница 11: ...or is affected by magnetism or static capacitance from an adjacent Sensor and the output is unstable One means of avoiding interference when mounting Proximity Sensors close together is to alternate S...

Страница 12: ...o do not use a Proximity Sensor to turn the power supply ON and OFF for electronic devices that use DC half wave rectification In such a case use a relay to turn the power supply ON and OFF and check...

Страница 13: ...sert the front of the Sensor into the special Mounting Bracket included or DIN Track 2 Press the rear of the Sensor into the special Mounting Bracket or DIN Track When mounting the side of the Sensor...

Страница 14: ...in series with an AND circuit the limit is three Sensors Be careful of the VS value in the diagram at left OR parallel connection In general it is not possible to use two or more Proximity Sensors in...

Страница 15: ...M1J T is 5 V Model Type of connection Connection Description DC 3 wire AND series connection Keep the number of connected Sensors N within the range of the following equation iL N 1 i Upper limit of...

Страница 16: ...or hot concentrated sulfuric acid Maintenance and inspection Periodic Inspection To ensure long term stable operation of the Proximity Sensor inspect for the following on a regular basis Conduct these...

Страница 17: ...may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control syst...

Отзывы: