background image

G-207

D4NH

D4

N

H

Miniature Safety-door Hinge Switch

D4NH

New series Safety-door Hinge 
Switch Designed for sace saving 
guaring in Machines and safety 
Equipment

• Lineup includes three contact models with 2NC/1NO and 

3NC contacts in addition to the 1NC/1NO, and 2NC ver-
sions. Version with MBB contacts meet applications for 
avdanced requirements.

• M12-connector models are available, saving on labor and 

simplifying maintenance.

• Standardized gold-clad contacts provide high contact reli-

ability Can be used with both standard loads and micro-
loads.

• Free of lead, cadmium, and hexavalent chrome, reducing the 

burden on the environment.

Be sure to read the “Safety Precautions” on page G-214.

Note: Contact your sales representative for details on models with safety standard

certification. 

Model Number Structure

1. Conduit/Connector size

1: Pg13.5 (1-conduit)
2: G1/2 (1-conduit)
3: 1/2-14NPT (1-conduit)
4: M20 (1-conduit)
5: Pg13.5 (2-conduit)
6: G1/2 (2-conduit)
7: 1/2-14NPT (2-conduit)
8: M20 (2-conduit)
9: M12 connector (1-conduit)

2. Built-in Switch

A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact) (slow-action)
F: 2NC/1NO (MBB contact) (slow-action)

3. Actuator

AS:

Shaft

BC:

Arm lever

Application Examples (Protective Door Safety Measures)

Shaft Actuator

Arm Lever Actuator

1 2 3

D4NH-

@@@

F502-EN2-04.book  Seite 207  Dienstag, 26. Juli 2005  5:48 17

Содержание D4NH -

Страница 1: ...of lead cadmium and hexavalent chrome reducing the burden on the environment Be sure to read the Safety Precautions on page G 214 Note Contact your sales representative for details on models with safety standard certification Model Number Structure 1 Conduit Connector size 1 Pg13 5 1 conduit 2 G1 2 1 conduit 3 1 2 14NPT 1 conduit 4 M20 1 conduit 5 Pg13 5 2 conduit 6 G1 2 2 conduit 7 1 2 14NPT 2 co...

Страница 2: ... D4NH 2ABC D4NH 2BBC D4NH 2CBC 1 2 14NPT D4NH 3ABC D4NH 3BBC D4NH 3CBC M20 D4NH 4ABC D4NH 4BBC D4NH 4CBC M12 connector D4NH 9ABC D4NH 9BBC 2 conduit Pg13 5 D4NH 5ABC D4NH 5BBC D4NH 5CBC G1 2 D4NH 6ABC D4NH 6BBC D4NH 6CBC 1 2 14NPT See note 3 D4NH 7ABC D4NH 7BBC D4NH 7CBC M20 D4NH 8ABC D4NH 8BBC D4NH 8CBC Actuator Conduit size Built in switch mechanism 3NC Slow action 1NC 1NO MBB Slow action 2NC 1N...

Страница 3: ... operation is possible with the ac tual load beforehand Agency Standard File No TÜV Product Service EN60947 5 1 approved direct opening B03 11 39656 061 UL See note UL508 CSA C22 2 No 14 E76675 Agency Standard File No CQC GB14048 5 Under application Item Utilization category AC 15 DC 13 Rated operating current Ie 3 A 0 27 A Rated operating voltage Ue 240 V 250 V Rated voltage Carry current Current...

Страница 4: ...k Safety Door Limit Switches for applications requiring safety door switches of tough high sealing or oil resistant construction A wide variety of conduits is available The arm lever is mounted upwards in the center position before shipping To change the position loosen the arm lever mounting screw dismount the arm lever and mount the arm lever in the left or right position Cam The joint between t...

Страница 5: ...chanism When metal deposition occurs the contacts are separated from each other by the plunger being pushed in Conforms to EN60947 5 1 Direct Opening Operation Contact spring Return spring Fixed contact NC Plunger Movable contact Both NC contacts have a direct opening mechanism When metal deposition occurs the contacts are separated from each other by the plunger being pushed in Conforms to EN6094...

Страница 6: ...oles Conduit cap See note 3 8 5 0 1 dia Depth 20 min 0 Two 4 0 15 dia holes Depth 5 D4NH 1 AS D4NH 2 AS D4NH 3 AS D4NH 4 AS D4NH 9 AS See note 4 OF max 0 15 N m PT 1 NC PT 2 NO 7 MBB 10 19 MBB 5 DOT min DOF min 18 1 N m Red Black 20 5 20 5 42 0 1 40 0 1 22 0 1 20 0 1 56 max 3 42 0 2 5 4 18 47 39 0 2 9 0 2 2 5 25 dia 30 20 5 11 0 2 21 5 28 2 13 0 2 18 dia 12 5 dia Two 3 2 0 1 dia 7 0 2 31 5 Two 3 2...

Страница 7: ...ote 3 0 Two 4 0 15 dia holes Depth 5 Cap 22 0 1 20 0 1 42 0 1 40 0 1 56 max 3 42 0 2 18 47 20 5 29 1 43 80 27 5 26 7 10 3 1 5 11 0 2 21 5 5 1 16 5 4 39 0 2 9 0 2 2 5 14 2 16 5 37 9 D4NH 5 BC D4NH 6 BC D4NH 7 BC D4NH 8 BC OF max 0 15 N m PT 1 NC PT 2 NO 7 MBB 10 19 MBB 5 DOT min DOF min 18 1 N m 14 M12 1 14 2 30 D4NH 9 When Installing at the Center The arm lever is set for center installation at th...

Страница 8: ...injuries or deaths use a model that has an NC contact equipped with a direct opening mechanism and make sure that the Switch operates in the direct opening mode Precautions for Correct Use Environment The Switch is intended for indoor use only Do not use the Switch outdoors Doing so may cause the Switch to malfunction Do not use the Switch where hazardous gases e g H2S SO2 NH3 HNO3 CI2 are present...

Страница 9: ...g for details on socket pin num bers and lead wire colors Socket Tightening Connector Type Turn the socket connector screws by hand and tighten until no space remains between the socket and the plug Make sure that the socket connector is tightened securely Other wise the rated degree of protection IP67 may not be maintained and vibration may loosen the socket connector Conduit Opening Connect a re...

Страница 10: ... Termination Following the release of the D4NH production of the D4DH will be terminated Date of Production Termination Production of the D4DH Series will be terminated in March 2006 Product Replacement 1 Dimensions The D4DH and D4NH use the same mounting method and mounting hole The multi contact structure and the extra 4 mm in length however are different 2 Terminal Numbers For the 2 contact mod...

Страница 11: ...a 12 5 dia Two 3 2 0 1 dia 31 5 Two 3 2 0 1 dia 2 15 0 05R mounting holes Conduit cap See note 8 5 0 1 dia Depth 20 min 0 Two 4 0 15 dia holes Depth 5 min 14 2 30 31 5 G 43 18 25 dia 2 5 5 4 20 0 1 22 0 1 40 0 1 42 0 1 42 0 2 56 max 3 50 9 0 2 39 0 2 28 2 8 11 0 2 7 0 2 3 2 0 1 dia 17 dia 27 5 19 13 0 2 20 5 20 5 12 5 dia Two 3 2 0 1 dia 2 15 0 05R mounting holes Cap 8 5 0 1 dia Depth 20 min 0 Two...

Страница 12: ...rest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No C131 E2 01A X ...

Отзывы: