G-214

Safety Sensors / Components

Safety Precautions

Refer to 

OMRON SAFETY COMPONENTS SERIES (Y106)

 for 

common precautions for Switches and Safety Limit Switches.

Do not use metal connectors or metal conduits with this Switch. 
Doing so may occasionally result in electric shock.

Precautions for Safe Use

Do not drop the Switch. Doing so may result in the Switch not 
performing to its full capacity.

Do not attempt to disassemble or modify the Switch. Doing so may 
cause the Switch to malfunction.

Do not use the Switch where explosive gas, flammable gas, or any 
other hazardous gas may be present.

Install the Switch in a location away from close body contact. Not 
doing so may result in malfunction.

Do not use the Switch submerged in oil or water, or in locations 
continuously subject to splashes of oil or water. Doing so may result 
in oil or water entering the Switch interior. (The IP67 degree of 
protection specification for the Switch refers to water penetration 
while the Switch is submersed in water for a specified period of 
time.)

Protect the head from foreign material. Subjecting the head to 
foreign material may result in premature wear or damage to the 
Switch. Although the switch body is protected from penetration by 
dust or water, the head is not protected from penetration by minute 
particles or water.

Turn the power OFF before wiring. Doing so may result in electric 
shock.

Install a cover after wiring. Not doing so may result in electric 
shock.

Connect a fuse to the Switch in series to protect the Switch from 
short-circuit damage. Use a fuse with a breaking current 1.5 to 2 
times larger than the rated current. To conform to EN ratings, use 
an IEC60269-compliant 10-A fuse type gI or gG.

Do not switch circuits for two or more standard loads (250 VAC, 
3 A) at the same time. Doing so may adversely affect insulation 
performance.

The durability of the Switch is greatly affected by operating 
conditions. Evaluate the Switch under actual working conditions 
before permanent installation and use within a number of switching 
operations that will not adversely affect the Switch’s performance.

Be sure to indicate in the machine manufacturer’s instruction 
manual that the user must not attempt to repair or maintain the 
Switch and must contact the machine manufacturer for any repairs 
or maintenance.

If the Switch is to be used in an emergency stop circuit or in a 
safety circuit for preventing accidents resulting in injuries or deaths, 
use a model that has an NC contact equipped with a direct opening 
mechanism and make sure that the Switch operates in the direct 
opening mode.

Precautions for Correct Use

Environment

The Switch is intended for indoor use only.

Do not use the Switch outdoors. Doing so may cause the Switch to 
malfunction.

Do not use the Switch where hazardous gases (e.g., H

2

S, SO

2

NH

3

, HNO

3

, CI

2

) are present or in locations subject to high 

temperature and humidity. Doing so may result in damage to the 
Switch caused by contact failure or corrosion.

Do not use the Switch under any of the following conditions.

Locations subject to extreme temperature changes.

Locations where high humidity or condensation may occur.

Locations subject to excessive vibration.

Locations where metal dust, processing waste, oil, or chemicals 
may penetrate through the protective door.

Locations subject to detergents, thinner, or other solvents.

Mounting Method

Mounting Screw Tightening Torque

Tighten each of the screws to the specified torque. Loose screws 
may result in malfunction of the Switch within a short time.

Switch Mounting

Mount the Switch using M4 screws and washers and tighten the 
screws to the specified torque.

For safety, use screws that cannot be easily removed, or use an 
equivalent measure to ensure that the Switch is secure.

Secure the Switch with two M4 bolts and washers. Provide studs 
with a diameter of 4

0.05

/

0.15

 and a height of 4.8 mm max. at two 

places, inserting into the holes at the bottom of the Switch as 
shown below so that the Switch is firmly fixed at four points.

Switch Mounting Holes

Mount the shaft or arm lever securely with a one-way screw, or an 
equivalent so that the shaft or arm lever cannot be easily removed.

Align the rotational center of the shaft with the door, so that the 
switch shaft and head will not be subjected to mechanical stress 
when the door opens or closes. 
Do not impose a force of 50 N or more on the shaft.

Be sure that the arm lever and door are mounted as shown in the fol-
lowing diagram so that the arm lever and head are not subjected to 
mechanical stress when the door opens or closes.

CAUTION

Terminal screw

0.6 to 0.8 N·m

Cover clamping screw

0.5 to 0.7 N·m

Head clamping screw

0.5 to 0.6 N·m

Arm lever clamping screw

1.6 to 1.8 N·m

Body clamping screw

0.5 to 0.7 N·m

Conduit mounting connection, M12 
adaptor

1.8 to 2.2 N·m

1.4 to 1.8 N·m (1/2-14NPT)

Cap screw

1.3 to 1.7 N·m

22

±

0.1

47

±

0.1

20

±

0.1

22

±

0.1

2.5

±

0.1

Two, M4

0.15

4

0.05

 dia.  

Height: 4.8 max.

42

±

0.1

39

±

0.1

20

±

0.1

22

±

0.1

40

±

0.1

42

±

0.1

2.5

±

0.1

5.35

±

0.1

Two, M4

0.15

4

0.05

 dia.  

Height: 4.8 max.

One-conduit Type

Two-conduit Type

F502-EN2-04.book  Seite 214  Dienstag, 26. Juli 2005  5:48 17

Содержание D4NH -

Страница 1: ...of lead cadmium and hexavalent chrome reducing the burden on the environment Be sure to read the Safety Precautions on page G 214 Note Contact your sales representative for details on models with safety standard certification Model Number Structure 1 Conduit Connector size 1 Pg13 5 1 conduit 2 G1 2 1 conduit 3 1 2 14NPT 1 conduit 4 M20 1 conduit 5 Pg13 5 2 conduit 6 G1 2 2 conduit 7 1 2 14NPT 2 co...

Страница 2: ... D4NH 2ABC D4NH 2BBC D4NH 2CBC 1 2 14NPT D4NH 3ABC D4NH 3BBC D4NH 3CBC M20 D4NH 4ABC D4NH 4BBC D4NH 4CBC M12 connector D4NH 9ABC D4NH 9BBC 2 conduit Pg13 5 D4NH 5ABC D4NH 5BBC D4NH 5CBC G1 2 D4NH 6ABC D4NH 6BBC D4NH 6CBC 1 2 14NPT See note 3 D4NH 7ABC D4NH 7BBC D4NH 7CBC M20 D4NH 8ABC D4NH 8BBC D4NH 8CBC Actuator Conduit size Built in switch mechanism 3NC Slow action 1NC 1NO MBB Slow action 2NC 1N...

Страница 3: ... operation is possible with the ac tual load beforehand Agency Standard File No TÜV Product Service EN60947 5 1 approved direct opening B03 11 39656 061 UL See note UL508 CSA C22 2 No 14 E76675 Agency Standard File No CQC GB14048 5 Under application Item Utilization category AC 15 DC 13 Rated operating current Ie 3 A 0 27 A Rated operating voltage Ue 240 V 250 V Rated voltage Carry current Current...

Страница 4: ...k Safety Door Limit Switches for applications requiring safety door switches of tough high sealing or oil resistant construction A wide variety of conduits is available The arm lever is mounted upwards in the center position before shipping To change the position loosen the arm lever mounting screw dismount the arm lever and mount the arm lever in the left or right position Cam The joint between t...

Страница 5: ...chanism When metal deposition occurs the contacts are separated from each other by the plunger being pushed in Conforms to EN60947 5 1 Direct Opening Operation Contact spring Return spring Fixed contact NC Plunger Movable contact Both NC contacts have a direct opening mechanism When metal deposition occurs the contacts are separated from each other by the plunger being pushed in Conforms to EN6094...

Страница 6: ...oles Conduit cap See note 3 8 5 0 1 dia Depth 20 min 0 Two 4 0 15 dia holes Depth 5 D4NH 1 AS D4NH 2 AS D4NH 3 AS D4NH 4 AS D4NH 9 AS See note 4 OF max 0 15 N m PT 1 NC PT 2 NO 7 MBB 10 19 MBB 5 DOT min DOF min 18 1 N m Red Black 20 5 20 5 42 0 1 40 0 1 22 0 1 20 0 1 56 max 3 42 0 2 5 4 18 47 39 0 2 9 0 2 2 5 25 dia 30 20 5 11 0 2 21 5 28 2 13 0 2 18 dia 12 5 dia Two 3 2 0 1 dia 7 0 2 31 5 Two 3 2...

Страница 7: ...ote 3 0 Two 4 0 15 dia holes Depth 5 Cap 22 0 1 20 0 1 42 0 1 40 0 1 56 max 3 42 0 2 18 47 20 5 29 1 43 80 27 5 26 7 10 3 1 5 11 0 2 21 5 5 1 16 5 4 39 0 2 9 0 2 2 5 14 2 16 5 37 9 D4NH 5 BC D4NH 6 BC D4NH 7 BC D4NH 8 BC OF max 0 15 N m PT 1 NC PT 2 NO 7 MBB 10 19 MBB 5 DOT min DOF min 18 1 N m 14 M12 1 14 2 30 D4NH 9 When Installing at the Center The arm lever is set for center installation at th...

Страница 8: ...injuries or deaths use a model that has an NC contact equipped with a direct opening mechanism and make sure that the Switch operates in the direct opening mode Precautions for Correct Use Environment The Switch is intended for indoor use only Do not use the Switch outdoors Doing so may cause the Switch to malfunction Do not use the Switch where hazardous gases e g H2S SO2 NH3 HNO3 CI2 are present...

Страница 9: ...g for details on socket pin num bers and lead wire colors Socket Tightening Connector Type Turn the socket connector screws by hand and tighten until no space remains between the socket and the plug Make sure that the socket connector is tightened securely Other wise the rated degree of protection IP67 may not be maintained and vibration may loosen the socket connector Conduit Opening Connect a re...

Страница 10: ... Termination Following the release of the D4NH production of the D4DH will be terminated Date of Production Termination Production of the D4DH Series will be terminated in March 2006 Product Replacement 1 Dimensions The D4DH and D4NH use the same mounting method and mounting hole The multi contact structure and the extra 4 mm in length however are different 2 Terminal Numbers For the 2 contact mod...

Страница 11: ...a 12 5 dia Two 3 2 0 1 dia 31 5 Two 3 2 0 1 dia 2 15 0 05R mounting holes Conduit cap See note 8 5 0 1 dia Depth 20 min 0 Two 4 0 15 dia holes Depth 5 min 14 2 30 31 5 G 43 18 25 dia 2 5 5 4 20 0 1 22 0 1 40 0 1 42 0 1 42 0 2 56 max 3 50 9 0 2 39 0 2 28 2 8 11 0 2 7 0 2 3 2 0 1 dia 17 dia 27 5 19 13 0 2 20 5 20 5 12 5 dia Two 3 2 0 1 dia 2 15 0 05R mounting holes Cap 8 5 0 1 dia Depth 20 min 0 Two...

Страница 12: ...rest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No C131 E2 01A X ...

Отзывы: