G-212
Safety Sensors / Components
Dimensions
Switches
Note: All units are in millimeters unless otherwise indicated.
Shaft Type with 1 Conduit
Shaft Type with 2 Conduits
Note: 1.
Unless otherwise specified, a tolerance of
±
0.4 mm applies to all dimensions.
2.
Variation occurs in the simultaneity of contact opening/closing operations of 2NC, 2NC/1NO, and 3NC contacts. Check contact operation.
3.
There are a minimum of five turns of the screw thread for a Pg13.5 conduit opening and four turns minimum for a G 1/2 conduit opening.
4.
Refer to the following diagram for details on M12 connectors.
1-conduit M12 Connector
Arm Lever Type with 1 Conduit
Red
Black
20.5
×
20.5
55
47
±
0.2
2.5
18
14.2
30
21.5
(31.5)
27.5
11
±
0.2
13
±
0.2
28
±
2
8
18 dia.
12.5 dia.
Two, 3.2
±
0.1
dia.
7
±
0.2
20
±
0.1
22
±
0.1
9
±
0.2
Two, 3.2
±
0.1
dia.
22
±
0.2
31
max.
2.15
±
0.05R
mounting holes
Conduit
cap
(See note 3.)
8.5
±
0.1 dia.
Depth: 20 min.
0
Two, 4
+0.15
dia. holes
Depth: 5
D4NH-1
@
AS
D4NH-2
@
AS
D4NH-3
@
AS
D4NH-4
@
AS
D4NH-9
@
AS (See note 4.)
OF max.
0.15 N·m
PT 1 (NC)
PT 2 (NO)
(7
°
) (MBB: 10
°
)
(19
°
) (MBB: 5
° )
DOT min.
DOF min.
18
°
1 N·m
Red
Black
20.5
×
20.5
42
±
0.1
40
±
0.1
22
±
0.1
20
±
0.1
56 max.
(3)
42
±
0.2
5.4
18
47
39
±
0.2
9
±
0.2
2.5
25 dia.
30
20.5
11
±
0.2
21.5
28
±
2
13
±
0.2
18 dia.
12.5 dia.
Two, 3.2
±
0.1
dia.
7
±
0.2
(31.5)
Two, 3.2
±
0.1
dia.
27.5
14.2
8
2.15
±
0.05R
mounting holes
Conduit cap
(See note 3.)
8.5
±
0.1 dia.
Depth: 20 min.
0
Two, 4
+0.15
dia. holes
Depth: 5
Cap
D4NH-5
@
AS
D4NH-6
@
AS
D4NH-7
@
AS
D4NH-8
@
AS
OF max.
0.15 N·m
PT 1 (NC)
PT 2 (NO)
(7
°
) (MBB: 10
°
)
(19
°
) (MBB: 5
°
)
DOT min.
DOF min.
18
°
1 N·m
(14)
M12
×
1
14.2
30
D4NH-9
@@@
Red
Black
20.5
×
20.5
2.15
±
0.05R
mounting holes
Conduit
cap
(See
note 3.)
0
Two, 4
+0.15
dia. holes
Depth: 5
29
±
1
2.5
18
20
±
0.1
22
±
0.1
55
43
80
±
1
5.1
16
11
±
0.2
21.5
(16.5)
27.5
(26.7)
(10.3)
1.5
(37.9)
22
±
0.2
31
max.
47
±
0.2
9
±
0.2
30
14.2
D4NH-1
@
BC
D4NH-2
@
BC
D4NH-3
@
BC
D4NH-4
@
BC
D4NH-9
@
BC (See note 4.)
OF max.
0.15 N·m
PT 1 (NC)
PT 2 (NO)
(7
°
) (MBB: 10
°
)
(19
°
) (MBB: 5
°
)
DOT min.
DOF min.
18
°
1 N·m
F502-EN2-04.book Seite 212 Dienstag, 26. Juli 2005 5:48 17